General information
8
Power Panel T30 User's manual V1.42 - Translation of the original documentation
Electrical components without a housing
The following points apply in addition to the points listed under "Electrical components with a housing":
•
Any persons handling electrical components or devices with installed electrical components must be
grounded.
•
Components are only permitted to be touched on their narrow sides or front plate.
•
Components must always be placed on or stored in a suitable medium (ESD packaging, conductive foam,
etc.).
Information: Metallic surfaces are not suitable storage surfaces!
•
Components must not be subjected to electrostatic discharge (e.g. caused by charged plastics).
•
Observe a minimum distance of 10 cm from monitors and television sets.
•
Measuring instruments and equipment must be grounded.
•
Probe tips of galvanically isolated measuring instruments must be temporarily discharged on suitably
grounded surfaces before taking measurements.
Individual components
•
ESD protective measures for individual components are thoroughly implemented at B&R (conductive floors,
footwear, arm bands, etc.).
•
Increased ESD protective measures for individual components are not required for handling B&R products
at customer locations.
1.2.4 Policies and procedures
Electronic devices are never completely failsafe. If the programmable logic controller, operating/monitoring device
or uninterruptible power supply fails, the user is responsible for ensuring that other connected devices such as
motors are brought to a safe state.
When using programmable logic controllers or operating/monitoring devices as control systems in connection with
a Soft PLC (e.g. B&R Automation Runtime or comparable product) or Slot PLC (e.g. B&R LS251 or comparable
product), safety precautions relevant to industrial control systems (e.g. the provision of safety devices such as
emergency stop, etc.) must be observed in accordance with applicable national and international regulations. This
also applies to all other devices connected to the system, such as drives.
All tasks such as the installation, commissioning and servicing of devices are only permitted to be carried out by
qualified personnel. Qualified personnel are those familiar with the transport, mounting, installation, commissioning
and operation of devices who also have the appropriate qualifications to perform these tasks (e.g. IEC 60364).
National accident prevention regulations must be observed.
The safety notices, information about connection conditions (nameplate and documentation) and limit values spec-
ified in the technical data must be read carefully before installation and commissioning and are to be observed
in all cases.
1.2.5 Transport and storage
During transport and storage, devices must be protected against undue stress (mechanical loads, temperature,
moisture, corrosive atmospheres, etc.).
Devices contain components sensitive to electrostatic charges that can be damaged by improper handling. It is
therefore necessary to provide the required protective measures against electrostatic discharge when installing or
"Protection against electrostatic discharge" on page 7
).
1.2.6 Installation
•
Installation must be performed according to this documentation using suitable equipment and tools.
•
Devices are only permitted to be installed by qualified personnel and when the power is switched off.
•
General safety guidelines and national accident prevention regulations must be observed.
•
Electrical installation must be carried out in accordance with applicable guidelines (e.g. wire cross sections,
fuses, protective ground connections).
•
Take the necessary protective measures against electrostatic discharge (see