![B&R 5AP1120.0573-000 User Manual Download Page 59](http://html1.mh-extra.com/html/bandr/5ap1120-0573-000/5ap1120-0573-000_user-manual_460435059.webp)
Technical data
Automation Panel 1000 user's manual V2.00
59
Model number
5AP1120.0573-000
Revision
D0
E0
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Degree of protection per EN 60529
Front: IP65
Back: IP20 (only with installed link module or installed system unit)
Degree of protection per UL 50
Front: Type 4X indoor use only
Mechanical properties
Front
4)
Frame
Aluminum, naturally anodized
Panel overlay
Material
Polyester
Light background color
RAL 9006
Dark border color around display
RAL 7024
Gasket
3 mm fixed gasket
Dimensions
Width
212 mm
Height
156 mm
Weight
1100 g
Table 4: 5AP1120.0573-000, 5AP1120.0573-000 - Technical data
1)
Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
At 25°C ambient temperature. Reducing the brightness by 50% can increase the half-brightness time by approximately 50%.
3)
Touch screen drivers for approved operating systems are available for download in the Downloads section of the B&R website (www.br-automation.com).
4)
Visual deviations in color and surface quality are possible due to process or batch conditions.
4.2.1.1.4 Dimensions
212
15
6
Figure 18: 5AP1120.0573-000 - Dimensions
4.2.1.1.5 Requirements
5.7" AP1000 panels are supported starting with the following firmware versions:
•
Firmware V03.11 or later with SDL/DVI receiver 5DLSDL.1001-00
•
Firmware V04.08 or later with SDL3 receiver 5DLSD3.1001-00
4.2.1.1.6 Temperature/Humidity diagram
T [°C]
0
100
100
0
-80
5
10
20
30
40
50
60
70
80
90
95
-60
-70
-50 -40 -30 -20 -10
90
80
70
60
50
40
30
20
10
RH [%]
(2)
(1)
Figure 19: 5AP1120.0573-000 ≥ Rev. E0 - Temperature/Humidity diagram
Diagram legend
(1)
Operation
T [°C] Temperature in °C
(2)
Storage and transport
RH [%] Relative humidity (RH) in percent and
non-condensing