Accessories
Automation Panel 1000 user's manual V2.00
165
9.4.6.1.6 Cable pinout
If you wish to assemble a suitable cable yourself, the cable must be wired according to this pinout.
Information:
Functionality is only guaranteed for the cables available from B&R.
P inout per TIA/EIA 568A
wh/gn
gn
wh/or
bl
wh/bl
or
wh/br
br
Shield
9.4.6.1.7 Wiring
The following information and figure apply if a field-assembled cable is used and connected to an RJ45 network
connector (e.g. patch panel) instead of directly to a B&R device.
The wiring must comply with category 6A (Cat 6A) or 7 (Cat 7) requirements. The maximum total length of 100
m is not permitted to be exceeded.
B&R device
B&R device
Patch panel
Patch panel
Patch cable
Patch cable
Field-assembled cable
Max. 5 m
Max. 100 m
Max. 5 m
Figure 93: Wiring with a field-assembled cable