A.5.2.3 10.4" devices
The cutout tolerance for the PP100/200, PP300/400, PP500, AP900, PPC700 and PPC800 is ±0.5 mm.
The cutout tolerance for the AP1000 is +0 mm / -0.5 mm.
323 x 260
10
10
8.5
8.5
Outer contour of device
Cutout for device
303 x 243
PP100/200/300/400
AP900/PPC700
PP100/200/300/400
AP1000
PP500
PP500
AP1000
AP900
Figure 106: Installation compatibility - 10.4" devices - Landscape1
10.4" Automation Panel 1000, Automation Panel 900, Panel PC 700, Power Panel 500, Power Panel 300/400 and
Power Panel 100/200 devices in Landscape1 format are 100% compatible.
Outer contour of device
Cutout for PP100/200/300/400 device
PP100/200/300/400
AP900/PPC700
Cutout for AP900/PPC700 device
4.
5
423 x 288
10
10
8.5
402 x 271
402 x 266.5
403 x 271
PP500
Cutout for PP500/AP1000 device
AP1000
0.5
13 PP100/200/300/400
8.5 AP900, PPC700
8.5 PP500, AP1000
Figure 107: Installation compatibility - 10.4" devices - Landscape2
10.4" Automation Panel 1000, Automation Panel 900, Panel PC 700 and Power Panel 500 devices are not 100%
compatible with Power Panel 300/400 or Power Panel 100/200 devices in Landscape2 format. Automation Panel
1000, Automation Panel 900, Panel PC 700 and Power Panel 500 devices need a cutout that is 4.5 mm larger
(bottom edge) and 0.5 mm wider (left and right).
The larger cutout can be used conditionally for all devices:
•
During installation, it is important to ensure that the PP100/200 and PP300/400 devices are positioned and
installed as centrally as possible in the cutout. If this is not the case, the retaining clips can no longer grip
and impermeability is no longer ensured by the circumferential cord gasket (IP65).