Technical data
4.1.2.2 Power calculation
In order to calculate the total power of the Automation Panel, the power rating of the display being used must be
added to the power rating of the link module being used.
Link modules
Type
Order number
Total power consumption of link module
SDL/DVI receiver
5DLSDL.1001-00
Max. 3.6 W
Max. 8.6 W (with USB consumer)
SDL3 receiver
5DLSD3.1001-00
Max. 8.1 W
Max. 13.1 W (with USB consumer)
SDL4 receiver
5DLSD4.1001-00
Max. 8.1 W
Max. 13.1 W (with USB consumer)
Panel
Display type
Model number
+5 V
3.3 V
+12 V
7.0" single-touch
5AP1120.0702-I00
-
1 W
6.5 W
10.4" single-touch
5AP1125.1043-I00
-
1.5 W
7.5 W
10.4" single-touch
5AP1125.1044-I00
-
1.5 W
7.5 W
15.0" single-touch
5AP1125.1505-I00
-
2.5 W
18 W
20