Technical data
Type
Model number
Storage [°C]
Transport [°C]
15.6" multi-touch
5AP933.156B-00 ≤ C0
-10 to 60
-10 to 60
15.6" multi-touch
5AP933.156B-00 ≥ D0
-25 to 70
-25 to 70
18.5" multi-touch
5AP933.185B-00 ≤ C0
-10 to 60
-10 to 60
18.5" multi-touch
5AP933.185B-00 ≥ D0
-20 to 60
-20 to 60
21.5" multi-touch
5AP933.215C-00 ≤ C0
-10 to 60
-10 to 60
21.5" multi-touch
5AP933.215C-00 ≥ D0
-20 to 60
-20 to 60
24.0" multi-touch
5AP933.240C-00 ≤ C0
-10 to 60
-10 to 60
24.0" multi-touch
5AP933.240C-00 ≥ D0
-25 to 70
-25 to 70
Link modules
Link module
Model number
Storage
Transport
SDL/DVI receiver
5DLSDL.1001-00
-20 to 60°C
-20 to 60°C
SDL3 receiver
5DLSD3.1001-00
-20 to 60°C
-20 to 60°C
SDL4 receiver
5DLSD4.1001-00
-20 to 60°C
-20 to 60°C
Table 2: Link modules - Ambient temperature during storage and transport
4.1.4.1.5 Temperature monitoring
A sensor in the display monitors the temperature of the AP1000 panel. For the position of the temperature sensor,
see
4.1.4.1.6 "Temperature sensor positions" on page 27
. The specified values in
represent the defined maximum temperature for this measurement point. An alarm is not
triggered if the temperature is exceeded. These temperatures can be read in BIOS or approved Microsoft Windows
operating systems using the B&R Control Center.
26
Automation Panel 1000 - Hygienic design user's manual V2.00