BANDIT CONTROLS - CE
3/19
76
8
245840062970 8Oct2018
MAINT3 2052 OUTPUTS
Yoke Disable is an output that disables yoke functions while in winch mode. The Yoke is momentarily enabled
during a forward feed assist but is otherwise disabled while in winch mode.
Feed FWD and Feed REV are the outputs that rotate the feed wheels into and away from the drum. The Feed
FWD and Feed REV each consist of two 4A outputs. Whenever Feed FWD or Feed REV is engaged, both
outputs are engaged simultaneously.
Winch In and Winch Out are 2A outputs. Winch In pulls the winch cable towards the stow position. Winch Out
extends the winch cable.
Yoke Up and Yoke Dn are 2A outputs. Yoke Up raises the yoke. Yoke Dn lowers the yoke.
Output status.
1=Healthy, 0=Bad.
Output On/Off Status
1=On, 0=Off