p. 46 - Frequently asked questions

Do I have to replace the 

HY-3 pack

 (liquid supply)  each 

time the unit has performed a fog expulsion, including 
false alarms?

No, 

BANDIT

 consumes ~28 ml. of HY-3 fluid each second 

of fog expulsion. A fully charged reservoir contains 

                                                   ~1400 ml.of HY-3 fluid. The unit can perform ~ 50 

seconds of fog expulsion. Depending on the adjusted fog 
expulsion period each alarm cycle leaves, a minimum of 
3 (big spaces, 200 M² with normal ceiling height of 2,80 
metre) to a maximum of 25 expulsion cycles in reserve. If 
the liquid level is beneath the adjusted minimum level, 
the unit will request to replace the 

HY-3 

pack. See page 

22 for further explanation.

What does replacing of the 

HY-3 pack 

mean?.

The 

HY3-pack 

is an ingenious combination of different parts:

- A pressure vessel: 2 pressure resistant stainless steel tubes. These contain the 

HY-3

 

liquid and the propellant under pressure, equal to the vapour pressure of the liquid 
pressure gas and the nitrogen after pressure filling. Both gasses are not inflammable, 
are ozone friendly and are not poisonous for humans or the environment.

- The electro valve: together with the liquid filter it forms an integral subpart of the HY-3 

pack. If the valve is opened by the 

BANDIT

-electronics, the  

HY-3

 liquid goes through 

the 

HY-3 pack

 ‘s liquid link in the hot heat exchanger for heating up and drying.

- The electronics: built-in to the 

HY-3 pack

. This little PCB contains a voltage regulator,  

temperature- and memory chip and a few components which take care of the 
communication with 

BANDIT

 main PCB. The purpose of these electronics is to 

“measure” how much fluid is present in the pressure vessel and to store all production 
and filling data of the 

HY-3 pack

.

If the pressure vessel is empty, you’ll have to replace it with a refilled one. The pressure 
vessel has to be returned for refilling. There, the still present fluid and propellant will be 
sucked out and recycled. The empty 

HY-3 pack

 will be automatically tested and refilled. 

The built-in memory chip will be updated and the “renewed” 

HY-3 pack

 is carefully re-

packed  to be sent to the customer.
This way, environment taxes and material costs are minimised. The high certainty of 
returning the empty 

HY-3 packs 

 for refilling is secured through the high purchase price 

for a new 

HY-3 pack

.

Does the 

HY-3

 fluid in the 

HY-3 

pack expire (decay) or does it loose its fog generating 

capacity after a certain period?

Contrary to those fog generators which hold their supply of fog fluid in a synthetic 
reservoir,  the 

HY-3

 fluid in the 

HY-3 pack

 is kept in an oxygen free, pressure 

environment, Ph stabilised, de-ionised, clean filled and hermetically sealed off from the 
outside world. Degeneration in the 

HY-3

 pack is thereby eliminated.

 

FAQ

FAQ

FAQ

FAQ

AQ

FAQ

F

AQ

FAQ

F

Q

FAQ

FA

FAQ

FAQ

FAQ

FAQ

FAQ

FAQ

FAQ

FAQ

FAQ

FAQ

Q

FAQ

FA

Q

A

F Q

A

F

FAQ

FAQ

F Q

A

F Q

A

Q

A

F Q

A

F

A

F Q

A

F Q

Q

FAQ

FA

A

F Q

A

F Q

FAQ

FAQ

F Q

A

F Q

A

Q

FAQ

FA

Q

A

F Q

A

F

A

F Q

A

F Q

A

F Q

A

F Q

Q

A

F Q

A

F

Q

A

F Q

A

F

F Q

A

F Q

A

A

F Q

A

F Q

F Q

A

F Q

A

F Q

A

F Q

A

Q

A

F Q

A

F

Q

A

F Q

A

F

Q

A

F Q

A

F

A

F Q

A

F Q

A

F Q

A

F Q

Q

A

F Q

A

F

Q

A

F Q

A

F

F Q

A

F Q

A

A

F Q

A

F Q

F Q

A

F Q

A

F Q

A

F Q

A

Q

A

F Q

A

F

Q

A

F Q

A

F

Q

A

F Q

A

F

BANDIT

 240

 

PB  

v.

408

Summary of Contents for 240 PB

Page 1: ...us communication Front LEDs 32 Audio 35 Event log 37 Passwords 38 Control Box 39 HY3 pack replacement 41 Maintenance 43 First aid 44 Schematic examples 45 Specifications 04 08 Frequently asked questio...

Page 2: ...objects by doing so burglary damage is effectively limited to a strict minimum Advantages Fills 1000 Ft 28 m of space per second of fog expulsion Extremely compact and discrete design A system free of...

Page 3: ...ffers a friendly Windows like users program It is advised to perform a yearly fog generator test See also Maintenance page 43 Standards Complies with European CE and EMC Standards Complies with Intern...

Page 4: ...main supply fuse to off In case of doubt immediately contact your BANDIT dealer or manufacturer mentioned on the back cover of this manual There are no repairable components inside the appliance Leave...

Page 5: ...ce second with 1 Ft eye object 230 PSI 1 6 Mpa 18 seconds 50 minutes from cold condition maximum 50 C 120 F and minimum 0 C 30 F 40 W hour 18 kW hour section 0 000016 In 0 004 mm full aerosol 1 4 litr...

Page 6: ...point in the direction of fragile objects The powerful fog expulsion could blow down these objects There has to be a free passage area for the ejected fog of at least 20 Ft before it bounces against a...

Page 7: ...it with included double sided adhesive tape The device is installed at 2 In 50 mm off the floor to avoid possible damage due to cleaning tools or water Hidden mounting of the appliance For installatio...

Page 8: ...980 Ft Fog image after 8 sec of fog expulsion The BANDIT 240 has a room filling capacity of 1000 Ft per second This corresponds with 100 Ft sec The max surface area which can be secured with one devic...

Page 9: ...al is warned Connection on the main power supply on the left beneath the PCB you ll find a 3 way terminal block with integrated main fuse The PCB is marked with 230 VAC supply Connect the left connect...

Page 10: ...input n 1 12 VDC supply max 500 mA Mains power supply connection block with integrated fuse 4 AT Mains power connecting cable min 1 5 mm 12 V c c c c c c Supply Xin1 Xin2 Xin3 Xin4 Tmpout OKout OKout...

Page 11: ...nal source or from the 12 V BANDIT supply source itself Supply the input current with 12 V is 10 mA each input each input is equipped with a Schmitt input after the opto coupler The trigger voltage is...

Page 12: ...operties of the guard mode 4The red LED Guard on the front panel will be on as long as the unit is in guard mode 4Eventual LED warnings on the front panel such as failure HY 3 and power Will be off un...

Page 13: ...vate the alarm mode through a negative or a positive edge F F If the optional remote control is connected channel 1 and or 2 can be set as additional alarm input s Using the software additional option...

Page 14: ...determined with the function of doorbell output this output will be active as long the doorbell audio signal is heard Activation of the door bell input 4While the unit is switched into guard mode Dep...

Page 15: ...he unit will sound The volume as well as the sounding period of this panic siren can be set speaker panic siren Activation of the panic input Depending on the software settings this input can start or...

Page 16: ...system is still in guard mode Properties of the warning mode 4If the function of an output is determined as warning output this output will be active as long as the warning mode is activated 4The mome...

Page 17: ...ending on the software settings this input can start the fire alarm mode when A negative or a positive voltage edge pulse an active puls will switch on the fire mode Following pulses have no influence...

Page 18: ...hed onto the fire alarm mode and an eventual active fire alarm mode will be interrupted 4A fire alarm off input can only be selected when there is also a fire alarm on input selected 4The switching of...

Page 19: ...d relay contact in serial with the existing tamper relay circuit Tmpout In high risk installations the fixed defined output Tmpout is integrated in the tamper circuit of the existing alarm system If i...

Page 20: ...g as the internal siren input is active but the internal Bandit electronics will reduce the audio volume after 3 minutes of sounding to 50 battery saving Activation of the internal siren input Only vo...

Page 21: ...l control is possible Depending on the software settings 0 V or 12 V can be set as active 4The internal siren will sound 4The time of activation as well as deactivation of this input will be logged 4I...

Page 22: ...cation until 10 seconds after the last communication signal If this Led blinks both batteries have to be replaced Sony CR2430 or compatible Yellow Led RS 232 communication Led Blinks simultaneously wi...

Page 23: ...ricted by F2 In normal conditions and with a full charged battery under charging current the voltage is 13 volt This voltage is practically ripple free 5mV ripple and serves as supply for small extern...

Page 24: ...See p 18 Based on the info of these different inputs the MCU software will decide whether to activate or not to activate the Tmpout relay Properties of the tamper mode The Tmpout relay is in rest pos...

Page 25: ...re gives you the possibility to bridge the HY 3 pack side hatch tamper contact e g when opening this hatch to change the HY 3 pack without causing a tamper alarm 7 BS software HY 3 pack R Software HY...

Page 26: ...fuse F3 6 3 A battery fuse is interrupted 4There is no battery or the voltage of the battery is too low 4The ambient temperature of the mounted HY 3 pack exceeds 120 F 4The heat exchanger can not rea...

Page 27: ...g Demo HY 3 pack in a regular device Tamper contact of the side hatch is bridged through the control box switch and or through software R HY 3 pack screen As soon as the internal failure is restored...

Page 28: ...ned trough software settings Max 500 mA 12 V t ol 0 V 12 V MCU Relais 12 V 1 A c c Xout com nc nc no no Block scheme BANDIT programmable outputs No function The output is always in rest position and i...

Page 29: ...it is as efficient as a visible outer siren For the owner it is a clear sign that BANDIT is in guard mode Function as long as BANDIT is in guard mode this Jumbo LED will blink 1 Hz A maximum of three...

Page 30: ...re is selected a warning input see page 15 it will be possible to select also a warning output The output follows always the status of the warning mode This output is used to extend the warning audio...

Page 31: ...t clicked on The output will be active as long as the guard on beep lasts but will be in rest when the guard off beep sounds Only Doorbell sound is clicked on This output can only be activated COM and...

Page 32: ...ble power supply failure is a very important function The solution for this eventual power supply failure is often the responsibility of the enduser while a battery problem is the responsibility of th...

Page 33: ...power supply is present the unit needs approximately 50 minutes from cold condition to reach its target temperature If BANDIT is in guard mode This green LED will be on This way the unit will never re...

Page 34: ...terrupted back to factory the internal 12 V charging voltage normally 13 1 13 2 V is too low If the main power supply is present BANDIT will perform a battery condition test each time the guard or bac...

Page 35: ...ossibility which automatically turns off the 4 s after the unit is put into guard mode 7 BS software Settings Edit Frontpanel The will regain their normal functionality from the moment the unit is put...

Page 36: ...o circuit The available signals are compiled into the flash memory of the MCU The preferred cy is presented through a high low and a digital potentiometer volume controller to the a u amplifier This o...

Page 37: ...at the unit is refusing to switch into the requested guard mode Usually this means that the moment the unit is put into guard mode one or more alarm inputs were already activated This could result imm...

Page 38: ...d disk in the directory pb240 events The file name of the saved file is generated automatically for example 2004_09_15__00_11_27 pdf This name exists out of the date time plus eventual device alias ti...

Page 39: ...ndit Change password installer password By entering first the actual valid old password the software will request the new password The BS software controls in real time the validity of the entered pas...

Page 40: ...d finished with a general insulation over the complete wire In the packing of the Control Box you ll find the mounting screws and nuts also a 6 way plug in connector with screw connection First insert...

Page 41: ...stays closed so no sabotage notice or fog expulsion while opening the side hatch The green LED on the switch is on The front LED internal failure blinks fast 2Hz This allows a fog ejection test each...

Page 42: ...olt red allen fixing bolt green HY 3 OK LED HY 3 hatch tamper pin M8 thread hole for HY 3 pack grip tool P 41 Replacement of HY 3 pack If the level seems to have gone below the adjusted minimum value...

Page 43: ...Y 3 pack connector and the liquid coupling are sliding over their respective connector and coupling Unscrew the HY 3 pack grip and fasten both red allen fixing bolts The green HY 3 pack LED will be on...

Page 44: ...ejection test is performed you ll have to warn all persons in the immediate surroundings and the responsible person for fire hazard Make sure no one is looking at the direction of the ejection mouth...

Page 45: ...tly persons who are over sensitive to stressing situations e g hyperventilate racing pulse etc persons who are strong asthmatic or exceptionally sensitive to irritation of the respiratory system child...

Page 46: ...even though BANDIT is functioning as supposed or if it is malfunctioning due to an internal or external failure We advise the installer to inform his insurance company that they will be installing fo...

Page 47: ...communication with BANDIT main PCB The purpose of these electronics is to measure how much fluid is present in the pressure vessel and to store all production and filling data of the HY 3 pack If the...

Reviews: