p. 34 - Communication status - LEDs - Front LEDs
N
HY-3 pack
(
HY-3 pack
liquid reserve
)
N
No mains power supply
(Power ?)
This red LED blinks as long the main power supply to
BANDIT ,
or its main fuse F1 is
interrupted
and
the unit is not in guard mode.
If
BANDIT
ge
t
s no main power supply for more than 2 hours, the internal heat
exchanger will cool down too much to function properly.
BANDIT
will notice this fact
and will refuse to perform any fog expulsion. A fog expulsion attempt with a cold
heat exchanger is wet and can cause damage to the surroundings (greasy layer on
textile, documents, furniture, etc...). The moment the main power supply is available
again, the unit will heat its heat exchanger to performing temperature and recharge
its internal battery.
F
F
F
If one chooses to have a hidden mounted application (/L option), the front LEDs often
are not visible anymore. It is suggested to use and install a “Control Box” in this case.
For details of Control Box see p. 42
Through the BS software there is also a setting possibility which automatically turns off
the
, 4
s after the unit is put into guard mode
-
7
BS-software -
;
Settings -
;
Edit -
;
Frontpanel
.
The
will regain their normal functionality from the moment the unit is put into
guard mode off
Some
ers prefer this setting While set this way, the unit will not reveal its presence
in the dark because the green
and the e
Guard
will be turned off.
front LEDs minute
.
front LEDs
.
install
.
OK-
r d “
” LED
With a new or refilled HY-3 pack on board,
BANDIT
disposes of 1.4 litre HY-3 liquid.
During a fog expulsion, approximately 28 ml of fluid is consumed each second.
So basically,
there is a total of ~55 seconds of fog expulsion available.
At ~70% of consumption of the HY-3 liquid, the unit will show through this LED the HY-3 pack
needs to be refilled.
Theoretically the HY-3 pack has no expiration date. But it is good practice and advised to
replace (new or refill) the HY-3 pack every 4 years, this ensures maximum reliability.
If this red HY-3 LED blinks, the
HY-3 pack
has to be exchanged (refilled).
As long as
BANDIT
is in guard mode, this LED will be off. This way, the unit will never show
through its front panel, to its surroundings, there might be a shortage on fog liquid.
BANDIT
240
PB
v.
408