Default Settings & Specifications
factory default settings
Default
Step
Minimum
Maximum
Maximum motor run time
40 seconds
-
-
-
Courtesy light time
4 minutes
(approx.)
-
-
-
Obstruction force margin
2
1
0
24
Auto-Close time
30 seconds
-
-
-
Technical specifications
Power supply
230V - 240Va.c. 50Hz
Transformer rating
24Va.c.
Standby power
2.0 Watts
Motor power
250 Watts (1/3 HP)
Motor type
Alternating Current
Maximum door opening: Width:
Height:
Area
Weight:
5500mm
3000mm
16.5m
2
100kg
Minimum headroom
50mm
Short term peak force
800N (80kg)
Lift force
600N (60kg)
Nominal force
150N (15kg)
Receiver type
UHF Multi-frequency FM Receiver
Receiver code storage capacity
14 X 4 button Transmitter Modes
Transmitter frequency
UHF Multi-frequency FM Transmitter
Coding type
Code hopping
Number of code combinations
Over 4.29 billion random codes
Code generation
Non-linear encryption algorithm
Transmitter battery
CR2032 (3 Volts)
Courtesy light
LED (Light Emitting Diodes)
Controller fuse
5A slow blow
Rated temperature
+5º to 40º
Note: Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure
on the door and tracks which may in turn intermittently trigger the safety obstruction detection system.