Setting Travel limits
nOTe:
The OPERATE button will not
function until the open and close limit
positions are set.
nOTe:
If a Safety Infra-red Beam is to be
used it must be installed before setting the
travel limits.
Step 15.1 - Set the Datum Position
Remove the controls cover to access the control
panel.
Move the door manually to engage the shuttle
assembly onto the chain index.
IMPORTAnT nOTe
- If the manual release
handle is more than 1.8 metres from floor level
when the opener is installed, extend the handle
to a height less than 1.8 metres.
Plug the power cord into a mains power point and
switch the power on. The CLOSE LIMIT LED should
be flashing
Press and hold the MINUS (-) or PLUS (+) button to
move the door to the halfway open position.
(fig. 25).
WARnInG:
The safety obstruction detection
system is inoperable while MINUS (-) and
PLUS (+) drive buttons are being used and
travel limits are not set.
Using a small blade screwdriver, turn the DATUM
ADJUST screw until the yellow SERVICE light comes
on
(fig. 26)
.
If the SERVICE light is already illuminated
when the door is halfway up, turn the
DATUM ADJUST screw until the light goes
off, then turn back one notch to illuminate
again.
Step 15.2 - Set the Close limit Position
Press and hold the MINUS (-) button until the door
reaches the desired close limit position. Single presses
of the button will inch the door closed
(fig. 27)
.
Press the LIMIT SET button to store the close position
into memory
(fig. 27)
.