6.7.2
Maximum Temperature
This setting is the maximum value the user may select, Tmax. Refer to Section 6.5.3 on page 23.
The current value is shown on the TEMP display, while M is shown on the VIT display.
Default value: 180
Parameter range: 1-180
◦
C (34-356
◦
F)
Precision: 1
◦
C
6.7.3
Operating Temperature
This setting establishes the operating temperature, TF. Refer to Section 6.4 on page 22.
The current value is shown on the TEMP display, while r is shown on the VIT display.
Default value: 130
Parameter range: 1-180
◦
C (34-356
◦
F)
Precision: 1
◦
C
6.7.4
Temperature Regulation
This setting defines the temperature setpoint regulation range.
The current value is shown on the TEMP display, while H is shown on the VIT display.
28