22
User Manual
IT8000 3/8” TIE
-LOK DATA TOOL
IT7000 1/4” TIE
-LOK DATA TOOL
ITC800 CONTROL SYSTEM
Document # P80080 Rev. C.3
© Copyright
BAND-IT-IDEX, Inc. 2024
All rights reserved
All rights reserved
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
TIE INSPECTION
CLAMP PLACEMENT
ss
Buckle location is critical to clamp performance. Use the following guidelines as a reference.
•
Do not install clamps at an angle (Fig. 30)
•
Buckle locations cannot be over air gaps (Fig. 32)
•
Avoid sharp corners, add largest radius possible on square corners (Fig. 31)
•
Tie-Lok® can be installed on flat surfaces
•
Do not install clamps on tapered surfaces or on tube bends (Fig.31)
•
Tie-Lok® advised min installed
diameter is 1”
•
The buckle area of the shield must be free of voids and wrinkles
For specific questions contact your BAND-IT-IDEX account manager.
Locking Dimple
The IT8000/IT7000 forms a locking dimple into the
Tie-Lok® Tie with the punch and cuts the remaining
tail. When installing a Tie-Lok® tie, a visual check is
recommended to verify the presence of a locking
dimple after the tie has been applied.
Figure 29
Figure 30
Figure 32
Figure 31