20
User Manual
IT8000 3/8” TIE
-LOK DATA TOOL
IT7000 1/4” TIE
-LOK DATA TOOL
ITC800 CONTROL SYSTEM
Document # P80080 Rev. C.3
© Copyright
BAND-IT-IDEX, Inc. 2024
All rights reserved
All rights reserved
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
Figure 24
SYNCING TOOL TO CONTROLLER
How to connect or replace an existing tool to the controller:
1.
Activate E-stop or turn controller off to disable air and power to motor.
2.
Disconnect data and motor cable to current tool (only required if a tool is connected).
3.
Disconnect pneumatic tubing harness to current tool (if required)
.
4.
Connect data and motor cable to new tool.
5.
Connect pneumatic tubing harness to new tool
.
6.
Release E-stop or turn controller back on. Ensure Door Latch is in the
On
position.
7.
Tool Setup automatically appears (skip step 1), if not go to settings screen (General tab)
1.
Select “
New Tool / Maintenance
”
2.
Select the Enter Serial Number field
3.
Type in
the new tool’s serial number
4.
Select
“Enter”
5.
Enter
“
Tool Cycle
Count”
6.
Select Maintenance Items that have been performed
7.
Select “Done” then “Yes” to confirm selections
8.
Input tool settings (If changing application)
1.
Set system pressure and punch pressure (Refer to settings, page 32)
2.
Set target torque (Refer to settings, page 32)
3.
Set ejection preference
9.
Message banner at top of screen should read "
Tool Ready
" and the tool is ready to use.
If an
error
is shown, press the error reset button.
Note: When powering on the controller, it takes approximately 30 seconds for the system to
be functional. Air pressure and motor power will not be activated until after this point.
E-Stop
Door Latch
Power Switch