SPECIAL PRECAUTIONS WHEN USING GAS.
•
Check that the feed line and the train comply with current law and
regulations.
•
Check that all the gas connections are properly sealed.
•
Do not leave the equipment on when it is not in use and always
close the gas cock.
•
If the user is absent for a prolonged period of time, close the main
gas feed tap to the burner.
•
If you smell gas:
-
do not operate electrical switches, phones or any other object
that may cause sparks;
-
open immediately doors and windows to create a draught to
clear the air in the room;
-
close the gas cocks;
-
have professionally qualified personnel correct the fault.
•
Do not obstruct ventilation openings in the room where there is
gas equipment. Otherwise, dangerous situations may arise with
the build up of toxic and explosive mixtures.
•
If the user is absent for a prolonged period of time, close the main
gas feed tap to the burner.
RESIDUAL RISKS
• Even though the product was designed in compliance with the
obligatory standards, residual risks may still be present during
correct operation. They are signalled on the burner through
special Pictograms.
CAUTION
Moving mechanical organs.
CAUTION
Materials at high temperature.
CAUTION
Powered electric panel.
PERSONAL PROTECTIVE EQUIPMENT
•
While working on the burner, use the following safety devices.
ELECTRIC SAFETY WARNINGS
•
Check that the equipment has a suitable ground system, carried
out following safety standards in force.
•
Have qualified personnel check that the electric system is ade
-
quate to equipment maximum power consumption indicated on
the plate.
•
For the mains supply connection, a unipolar switch with a contact
opening gap equal or above 3 mm in accordance with current sa
-
fety regulations (condition of overvoltage category III) is required.
•
Remove the external insulating seal of the supply pipe necessary
for the connection, preventing the cable to touch metal parts.
•
The use of any electrically fed components entails complying with
certain fundamental rules, including the following:
-
do not touch the equipment with parts of the body that are wet
or damp or with damp feet;
-
do not pull on electrical cables;
-
do not leave the equipment exposed to atmospheric agents
(such as rain or sun etc.) unless there is explicit provision for
this;
-
do not allow the equipment to be used by children or inexpert
persons;
-
The power supply cable for the equipment must not be replaced
by the user. If the cable is damaged, turn the equipment off and
disconnect it from the main power supply. To replace it contact
qualified personnel only.
-
If you decide not to use the equipment for a certain period of
time it is advisable to switch off the electrical power supply to all
components in the system that use electricity (pumps, burner,
etc.).
•
Use regulation-compliant flexible cables EN60335-1:EN 60204-1
-
in case of PVC sheath, at least type H05VV-F;
-
in case of rubber sheath, at least type H05RR-F; LiYCY
450/750V
-
without any sheath, at least type FG7 o FROR, FG70H2R
-
in case of PVC sheath, at least type H05VV-F;
-
in case of rubber sheath, at least type H05RR-F; LiYCY
450/750V
-
without any sheath, at least type FG7 o FROR, FG70H2R
•
The electric equipment works correctly when the relative humidity
does not exceed the 50% at a maximum temperature of +40° C.
Higher relative humidity are allowed at lower temperatures (e.g.
90 % at 20° C)
•
The electric equipment works correctly at altitudes of up to 1000
m above the see level.
IMPORTANT
We hereby declare that our gas, liquid and mixed forced draught
burners respect the minimum requirements of the European
Directives and Regulations and are compliant with European
standards.
A copy of the EC declaration of conformity is supplied with the
burner.
4 / 32
0006160085_202304
ENGLISH
Summary of Contents for TBG 45 MC
Page 2: ......
Page 33: ...YP 31 32 0006160085_202304 ITALIANO...
Page 65: ...YP 31 32 0006160085_202304 ENGLISH...
Page 67: ......