Completely remove the mixing unit, pulling it out in the direction
shown by arrow (18), after pulling the ignition and ionisation
cables (14) out of their electrodes (figure 4).
Complete maintenance operations, proceed with re-assembly of the
combustion head, following the above instructions in reverse order,
after having checked for the correct position of the ignition and ioni
-
sation electrodes (see the COMBUSTION HEAD AND ELECTRODE
DISK DISTANCE REGULATION diagram).