REDUCERS ASSEMBLY INSTRUCTIONS FOR LPG
In the event of functioning with LPG fuel connect the appropriate
reducers supplied with the burner.For the assembly of the reducers
follow the instructions below.
TBG 35 MC
0002935830a
A
1
A
1) After loosening the fastening screws 1 remove the two reducers A
(N.2) from their respective seats.
0002935830b
2) Insert the two reductions B with holes facing towards the external
part of the mixer.
0002935830c
3) Position the slits C flush with the flame disc D as shown in the
figure; suitably secure the new reducers using the corresponding
screws.
CAUTION / WARNINGS
In some particular applications, in the event that there are
pulsations in the flame during the functioning of the burner with
natural gas, it is advisable to use the intended reducers for LPG
fuel.