WARNING NOTES FOR THE USER HOW TO USE THE BURNER SAFELY

FOREWORD 

These warning notes are aimed at ensuring the safe use of the components of heating systems for civil use and the production of hot water. 
They indicate how to act to avoid the essential safety of the components being compromised by incorrect or erroneous installation and by 
improper or unreasonable use. The warning notes provided in this guide also seek to make the consumer more aware of safety problems in 
general, using necessarily technical but easily understood language. The manufacturer is not liable contractually or extra contractually for any 
damage caused by errors in installation and in use, or where there has been any failure to follow the manufacturer’s instructions.

GENERAL WARNING NOTES 

•  The instruction booklet is an integral and essential part of the product and must be given to the user. Carefully read the warnings in the 

booklet as they contain important information regarding safe installation, use and maintenance. Keep the booklet to hand for consultation 
when needed. 

•  Equipment must be installed in accordance with current regulations, with the manufacturer’s instructions and by qualified technicians. By 

the term ‘qualified technicians’ is meant persons that are competent in the field of heating components for civil use and for the production 
of hot water and, in particular, assistance centres authorised by the manufacturer. Incorrect installation may cause damage or injury to 
persons, animals or things. The manufacturer will not in such cases be liable. 

•  After removing all the packaging make sure the contents are complete and intact. If in doubt do not use the equipment and return it to the 

supplier. The packaging materials (wooden crates, nails, staples, plastic bags, expanded polystyrene, etc.) must not be left within reach of 
children as they may be dangerous to them. They should also be collected and disposed on in suitably prepared places so that they do no 

pollute the environment. 

•  Before carrying out any cleaning or maintenance, switch off the equipment at the mains supply, using the system’s switch or shut-off systems. 

•  If there is any fault or if the equipment is not working properly, de-activate the equipment and do not attempt to repair it or tamper with 

it directly. In such case get in touch with only qualified technicians. Any product repairs must only be carried out by BALTUR authorised 
assistance centres using only original spare parts. Failure to act as above may jeopardise the safety of the equipment. To ensure the effi

-

ciency and correct working of the equipment, it is essential to have periodic maintenance carried out by qualified technicians following the 

manufacturer’s instructions. 

•  If the equipment is sold or transferred to another owner or if the owner moves and leaves the equipment, make sure that the booklet always 

goes with the equipment so it can be consulted by the new owner and/or installer.

•  For all equipment with optionals or kits (including electrical), only original accessories must be used. 

BURNERS 

•  This equipment must be used only for its expressly stated use: applied to boilers, hot air boilers, ovens or other similar equipment and not 

exposed to atmospheric agents. Any other use must be regarded as improper use and hence dangerous. 

•  The burner must be installed in a suitable room that has ventilation in accordance with current regulations and in any case sufficient to 

ensure correct combustion 

•  Do not obstruct or reduce the size of the burner’ air intake grills or the ventilation openings for the room where a burner or a boiler is installed 

or dangerous mixtures of toxic and explosive gases may form. 

•  Before connecting the burner check that the details on the plate correspond to those of the utility supplies (electricity, gas, light oil or other fuel). 

•  Do not touch hot parts of the burner. These, normally in the areas near to the flame and any fuel pre-heating system, become hot when the 

equipment is working and stay hot for some time after the burner has stopped. 

•  If it is decided not to use the burner any more, the following actions must be performed by qualified technicians:

  a) Switch off the electrical supply by disconnecting the power cable from the master switch. 

  b) Cut off the fuel supply using the shut-off valve and remove the control wheels from their position.

  c) Render harmless any potentially dangerous parts.

Special warning notes 

•  Check that the person who carried out the installation of the burner fixed it securely to the heat generator so that the flame is generated 

inside the combustion chamber of the generator itself. 

•  Before starting up the burner, and at least once a year, have qualified technicians perform the following operations: 

a) Set the burner fuel capacity to the power required by the heat generator.

b) Adjust the combustion air flow to obtain combustion yield of at least the minimum set by current regulations.

c) Carry out a check on combustion to ensure the production of noxious or polluting unburnt gases does not exceed limits permitted by 

current regulations. 

d) Check the adjustment and safety devices are working properly. 

e) Check the efficiency of the combustion products exhaust duct. 

f) Check at the end of the adjustments that all the adjustment devices mechanical securing systems are properly tightened. 

g) Make sure that the use and maintenance manual for the burner is in the boiler room.

•  If the burner repeatedly stops in lock-out, do not keep trying to manually reset but call a qualified technicians to sort out the problem.

•  The running and maintenance of the equipment must only be carried out by qualified technicians, in compliance with current regulations.

Summary of Contents for SPARKGAS 20P - 20PW

Page 1: ...truzioni per bruciatori modello Instruction for burners model Instrucci nes para quemadores modelos Mode d emploi brule r SPARKGAS20P 20PW SPARKGAS30P 30PW SPARKGAS35P 35PW 0006080480_200710 IT GB SP...

Page 2: ......

Page 3: ...rous accidents SP Antes de empezar a usar el quemador lea detenidamente el folleto ADVERTENCIAS DIRIGIDAS AL USUARIO PARA USAR CON SEGURIDAD EL QUEMADOR que va con el manual de instruc ciones y que co...

Page 4: ...ram with vaporisation 58 Adjustment diagram for servomotor 59 Air regulation principle Electrodes adjustment 60 Electric diagram 62 SOMMAIRE PAGE Caracteristiques techniques 15 Application du br leur...

Page 5: ...997 A1 2001 EN 55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1 2001 EN 50366 2004 A1 2006 EN 61000 3 2 2000 A2 2005 Organo di Sorveglianza secondo la Direttiva Gas 90 396 CEE CE0085 DVGW Statement of...

Page 6: ...55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1 2001 EN 50366 2004 A1 2006 EN 61000 3 2 2000 A2 2005 rgano de Vigilancia seg n la Directiva Gas 90 396 CEE CE0085 DVGW D claration de conformit Nous d...

Page 7: ...e si dovesse traslocare e lasciare l apparecchio assicurarsi sempre che il libretto accompagni l apparecchio in modo che possa essere consultato dal nuovo proprietario e o dall installatore Per tutti...

Page 8: ...compromettere il buon funzionamento del bruciatore Per la prima messa in funzione dell apparecchio far effettuare da personale professionalmente qualificato le seguenti verifiche a il controllo della...

Page 9: ...equipment is sold or transferred to another owner or if the owner moves and leaves the equipment make sure that the booklet always goes with the equipment so it can be consulted by the new owner and o...

Page 10: ...by qualified technicians and in compliance with current law and regulations since incorrect installation may cause damage to person animals or things for which damage the manufacturer shall not can b...

Page 11: ...sted se muda de casa y deja el aparato hay que asegurarse siempre de que el libro de instrucciones est siempre con el aparato para que pueda ser consultado por el nuevo propietario y o instalador Para...

Page 12: ...n comprometer el buen funcionamiento del quemador La primera vez que se pone en funcionamiento el aparato el personal cualificado profesionalmente tiene que controlar a la estanqueidad en el tramo int...

Page 13: ...appareil doit tre vendu ou transf r un autre propri taire ou si celui ci doit d m nager et laisser ce dernier toujours v rifier que la notice accompagne l appareil afin qu il puisse tre consulter par...

Page 14: ...le bon fonctionnement du br leur Lors de la premi re mise en service de l appareil faire effectuer les v rifications suivantes par du personnel qualifi a le contr le de l tanch it de la partie interne...

Page 15: ...PRESSURE PRESSION METANO PRESION GAZ NATUREL mbar 15 23 13 19 13 21 PRESSIONE G P L L P G PRESSURE PRESSION G P L PRESION G P L mbar 30 MOTORE MOTOR MOTEUR 230V 50Hz 250 W 2800 Giri min r p m 370 W 2...

Page 16: ...AS 20W 475 230 245 562 5 262 5 300 170 740 120 280 126 95 3 4 105 M8 130 SPARKGAS 30 490 245 245 637 275 362 200 860 170 300 135 135 1 1 4 140 175 M12 150 SPARKGAS 30W 475 230 245 625 262 5 362 200 83...

Page 17: ...bustion 11 Joint isolant 12 Bride de fixation br leur 13 Couvercle br leur 14 Vis de r glange de disque t te 15 Electrovanne gaz 1 Control box 2 Reset button 3 Fan motor 4 Manual switch 5 Connectors 6...

Page 18: ...one del gas all esterno della centrale termica un adatto riduttore di pressione Consigliamo di installare una curva direttamente sulla rampa gas del bruciatore prima di applicare il raccordo smontabil...

Page 19: ...ion pipeline Only if the gas pressure were above the maximum value allowed by regulations 400 mm W C would it be necessary to install a pressure reducer on the gas pipeline outside the heating plant W...

Page 20: ...r 2 Open the combustion air regulator to the appropriate level see air shutter control servo regulation type STA 5 B 0 36 8 3N23 and open the air passage between the head and the flame disk diffuser t...

Page 21: ...2932171 The combustion head is equipped with a regulating device which closes and opens the air passage between the disk and the head By closing the passage it s possible to achieve high pressure upst...

Page 22: ...combustion in let gate very closed The block positionisasafetyposition reached by the burner automatically when some of the components of the burners or the plant do not work pro perly It is necessar...

Page 23: ...32 63 0006080480_200710...

Page 24: ...33 63 0006080480_200710...

Page 25: ...ple valve 1st and 2nd flame 9 Regulating ring 1st flame delivery 10 Regulating knob 2nd flame delivery 11 Protective cover can be used as a knob of regulating device for the initial rapid release Note...

Page 26: ...e 8 Regulating the initial rapid release effects the 1st and 2nd opening positions of the valve Regulation of the rapid release andof the hydraulic brake modify the 1st and 2nd positions of the valve...

Page 27: ...s area and a minimum of 0 5 m2 At least one third of the entire surface of these inlets must be located in the lower part of the external wall flush with the floor 3 Requirements for liquid gas plant...

Page 28: ...e position of the electrodes ends 3 Check the setting and operation of the air pressure switch 1 Check the position of the control electrode Check the valve of the ionisation current TYPE OF IRREGULAR...

Page 29: ...aggio aria tra disco e testa svitare per chiudere 1 Elettrodo ionizzatore 2 Elettrodo accensione B head disk adjustment screw tighten to open the head disk air passage loosen to shut 1 Ionizing electr...

Page 30: ...CONEXI N V LVULA 2a LLAMA HAY QUE REGULARLA ENTRE LA LEVA DE 1a LLAMA Y DE LA 2a LLAMA 5 LEVA CLAPETA AIRE CERRADACON QUEMADOR PARADO 6 LEVA DE REGULACI N AIRE 2a LLAMA 7 CONEXIONES EL CTRICAS 8 NDIC...

Page 31: ...61 63 0006080480_200710...

Page 32: ...62 63 0006080480_200710...

Page 33: ...63 63 0006080480_200710...

Page 34: ...La Casa por lo tanto se reserva cualquier posibilitad de modificati n de datos t cnicos y otras anotaciones Ce manuel rev t caract re purement indicatif La maison se reserve la possibilit de modifier...

Reviews: