• If there is any fault or if the equipment is not working properly,
de-activate the equipment and do not attempt to repair it or tamper
with it directly. Contact only qualified personnel.
•
Any product repairs must only be carried out by BALTUR authori
-
sed assistance centres or by its local distributor using only original
spare parts.
•
The manufacturer and/or its local distributor are not liable for any
accident or damage caused by unauthorised changes of the pro
-
duct and by failure to follow the rules described in the manual.
SAFETY WARNINGS FOR INSTALLATION
•
The equipment must be installed in a well-ventilated suitable room
in compliance with the laws and regulations in force.
• Ventilation grille section and installation room aeration openings
must not be obstructed or reduced.
•
The installation room must NOT have the risk of explosion and/
or fire.
• Before installing the equipment we recommend to carefully clean
the interior area of all fuel supply system pipes.
• Before connecting the equipment check that the details on the plate
correspond to those of the utility supplies (electricity, gas, light oil
or other fuel).
•
Make sure the burner is firmly fixed to heat generator according to
manufacturer instructions.
• Connect to the source of energy according to state-of-the-art stan-
dards as described in the explanatory diagrams and in compliance
with the regulatory and law requirements in force at the moment of
installation.
•
Check that the fume disposal system is NOT obstructed.
•
If it is decided not to use the burner any more, the following proce
-
dures must be performed by qualified technicians:
-
Switch off the electrical supply by disconnecting the power
cable from the main switch.
- Cut off the fuel supply using the shut-off valve and remove the
control wheels from their position.
- Render harmless any potentially dangerous parts.
WARNINGS FOR START UP, TEST, USE AND MAINTENANCE
•
Start up, test and maintenance of the equipment must only be car
-
ried out by qualified technicians, in compliance with current regu
-
lations.
•
Once the burner is fixed to the heat generator, make sure that the
generated flame does not come out of any slot during testing.
• Check equipment fuel supply pipe seal.
•
Check that fuel flow rate equals the power required to the burner.
•
Set the burner fuel capacity to the power required by the heat ge
-
nerator.
•
Fuel supply pressure must be within the values indicated on the
plate on the burner and/or manual
•
The fuel supply system is suitably sized for the flow required by the
burner and that it has all the safety and control devices required by
current standards.
•
Before starting up the burner, and at least once a year, have quali
-
fied technicians perform the following operations:
-
Set the burner fuel capacity to the power required by the heat
generator.
-
Check combustion and adjust combustion and/or fuel air flow to
optimize combustion and reduce emissions in accordance with
the law in force.
- Check the adjustment and safety devices are working properly.
-
Check the efficiency of the combustion products exhaust duct.
-
Check seal in the fuel supply pipe internal and external section.
- At the end of the adjustment procedures, check that all the
locking devices of mechanical securing systems are properly
tightened.
-
Make sure that the use and maintenance manual of the burner
is available.
•
If the burner repeatedly stops in lock-out, do not keep trying to ma
-
nually reset it but call a qualified technician.
•
If you decide not to use the burner for a while, close the valve or
valves that supply the fuel.
ENGLISH
3 / 28
0006160053_201912
Summary of Contents for BTG 12
Page 2: ......
Page 29: ...SCHEMI ELETTRICI ITALIANO 27 28 0006160053_201912...
Page 57: ...WIRING DIAGRAMS ENGLISH 27 28 0006160053_201912...
Page 59: ......