www.balluff.com
5
english
2.1
Intended use
The BTL6 Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories. Use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
2.2
General safety notes for the position
measuring system
Installation
and
startup
may only be performed by
trained specialists with basic electrical knowledge.
Specialists are those who can recognize possible hazards
and institute the appropriate safety measures due to their
professional training, knowledge, and experience, as well
as their understanding of the relevant regulations pertaining
to the work to be done.
The
operator
is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take steps to ensure that a
defect in the position measuring system will not result in
hazards to persons or equipment.
If defects and unresolvable faults occur in the transducer, it
should be taken out of service and secured against
unauthorized use.
2.3
Explanation of the warnings
Always observe the warnings in these instructions and the
measures described to avoid hazards.
The warnings used here contain various signal words and
are structured as follows:
SIGNAL WORD
Hazard type and source
Consequences if not complied with
f
Measures to avoid hazards
The individual signal words mean:
NOTICE!
Identifies a hazard that could
damage
or
destroy the
product
.
DANGER
The general warning symbol in conjunction with the
signal word DANGER identifies a hazard which, if not
avoided,
will certainly result in death
or
serious
injury
.
2.4
Disposal
f
Observe the national regulations for disposal.
2
Safety
BTL6-V1 _ E-M _ _ _ _ -A1-S115
Micropulse AT transducer in round profile housing
Summary of Contents for BTL6-V1 E-M Series
Page 1: ...BTL6 V11E M0500 A1 S115 BTL1035 BTL6 V1 _ E M _ _ _ _ A1 S115 Betriebsanleitung deutsch...
Page 2: ...www balluff com...
Page 18: ...BTL6 V11E M0500 A1 S115 BTL1035 BTL6 V1_E M_ _ _ _ A1 S115 User s Guide english...
Page 19: ...www balluff com...
Page 35: ...BTL6 V11E M0500 A1 S115 BTL1035 BTL6 V1_E M_ _ _ _ A1 S115 Manual de instrucciones espa ol...
Page 36: ...www balluff com...
Page 52: ...BTL6 V11E M0500 A1 S115 BTL1035 BTL6 V1_E M_ _ _ _ A1 S115 Notice d utilisation fran ais...
Page 53: ...www balluff com...
Page 69: ...BTL6 V11E M0500 A1 S115 BTL1035 BTL6 V1_E M_ _ _ _ A1 S115 Manuale d uso italiano...
Page 70: ...www balluff com...