Writing 8 bytes of user data (1122334455667788) to TAG with
EPC 0102030405060708090A0B0C
hex
from address 0.
1. Command
: 'WE'000000000C0B0A090807060504030201'U
˽
000000000008
˽
˽
'
1122334455667788<LF><CR>
'WE' 00…0C 'U
˽
000000 000008
˽
˽
' 11…88 <LF><CR>
Writing to data carrier
with EPC
EPC of data carrier
1)
Only user data, no TID
Start address
No. of bytes
Reserved
Data block
2)
End identifier
2. Reply:
<ACK>'0'<LF><CR>
<ACK>
'0'
<LF><CR>
Acknowledgment
Status message 'No error'
End identifier
1) Fully recognized EPC: 0102030405060708090A0B0C
hex
, filled to 16 bytes with 00000000
hex
.
2) Data block 8 bytes: Address 0: 11
hex
, Address 1: 22
hex,
Address 3: 33
hex
,... Address 7: 88
hex
.
Telegram