BIS U-602_ Processor Unit
TCP/IP / RS232
25
User data start address
Start address of the USER data for automatic reading during data carrier searches and if USER
data is used as an address during reading or writing.
Factory setting:
0 bytes
User data length
Length of the USER data for automatic reading during data carrier searches and if USER data is
used as an address during reading or writing. The value range is 1 to 16.
Factory setting:
16 bytes
TID length
Length of the TID data for automatic reading during data carrier searches and if TID data is used
as an address during reading or writing. The value range is 2 to 12.
Factory setting:
12 bytes
Note
Data carriers with a TID length different than that set here are not answered in the
detection, read and write commands.
7.6 Reading/writing
Tag Field Lengths
area
7
Setting the Processor Unit Parameters