www.balluff.com
BIS U-602_ Processor Unit
TCP/IP / RS232
37
Writing data (such as EPC or USER data) to recognized data carriers.
The TID cannot be modified.
Note
For data carriers with the same identification, all data carriers are answered.
1. Controller sends:
Com-
mand
ID type ID
1)
Data
type
Reser-
ved
Start
address
2)
Number of
bytes
2)
Reser-
ved
3)
Data End identifier
Character
'W'
'T'
or
'E'
or
'e'
or
'U'
[...]
4)
'E' or
'e'
or
'U'
'
˽
'
'000000'
to
'999999'
'000001'
to
'001024'
'
˽
˽
'
[...]
4)
CRC-16
or
<LF><CR>
Byte length
1
1
16
or
64
1
1
6
6
2
Variable
2
2. Processor unit replies
:
Reply
Status number
End identifier
Character
<ACK>
'0'
CRC-16
or
<LF><CR>
Byte length
1
1
2
or
Reply
Status number
End identifier
Character
<NAK>
CRC-16
or
<LF><CR>
Byte length
1
1
2
Content of the ID or data fields if ID type or data type = EPC and EPC format = 496 bits (62
bytes) is set:
No. of bytes
EPC
Character
'02'…'62'
[...]
4)
Byte length
2
62
1) Length of the "ID" field depends on the selected EPC format.
2) Start address and number of bytes refer only to the reading in the user area (U). EPC and TID are always transferred in
their full length. Values depend on the data carrier being used.
3) Any character can be allocated to reserved bytes, which are ignored in commands to the BIS U.
4) Placeholder for data block. The data is sent aligned to the right and the remaining characters filled with 0x00. Only the
right-aligned values from the programmed number of bytes are evaluated.
Telegram
Write (W)
8
Device Function
Summary of Contents for BIS U-6020-053-10 RS232
Page 2: ...www balluff com...