background image

www.balluff.com

3

english

Dimensional drawings

Fig. 2: 

M12×1

15

G1/4

Ø 6

L

19

Process connection with round threads

Fig. 3: 

M12×1

15

1/4NPT

Ø 6

L

19

Process connection with tapered threads

  WARNING

Health hazard!

Measuring materials which are irritating, toxic, 
carcinogenic, radioactive etc. represent a health hazard.

 

Remove all residual measuring material remnants 
before returning, storing or disposing of the screw-in 
thermometer.

  CAUTION

Combustion hazard!

When installing and removing there is a risk from 
escaping hazardous hot measuring materials.

 

Allow the screw-in thermometer to cool down before 
removing!

 

Screw-in thermometer must be installed and 
removed only when not under pressure!

Install the screw-in thermometer such that the permissible 

operating temperature (ambient, measuring material) is 

neither too hot nor too cold taking into account convection 

and thermal radiation.

Installation example

Fig. 4:   

b

a

c

Installation 

length A

Installation on tubes
a on angle piece
b in smaller tube, tilted
c vertical to direction of flow

Installation

Specifications for the threaded mounting holes can be 

found in DIN 3852 and for NPT threads in ANSI B 1.20.

Sealing

To seal the process connections with round threads at the 

sealing surface (see Fig. 5) use flat gaskets, sealing lenses. 

For tapered threads (e.g. NPT threads) seal the threads 

using for example PTFE tape (EN 837-2).

Fig. 5: 

Sealing surface

Process connection sealing

Installation and disassembly

Screw-in thermometer with plug connection

BFT _ _ _ _-_ _001-R_ _A0A-_ _

Summary of Contents for BFT Series

Page 1: ...deutsch Betriebsanleitung english User s guide fran ais Notice d utilisation italiano Manuale d uso espa ol Manual de instrucciones BFT _ _ _ _ _ _001 R_ _A0A _ _...

Page 2: ...www balluff com...

Page 3: ...er mit Steckeranschluss diese Anleitung Benutzerhinweise Das in der Betriebsanleitung beschriebene Einschraub Thermometer wird nach den neuesten Erkenntnissen konstruiert und gefertigt Alle Komponente...

Page 4: ...einen Regeln hinaus die einschl gigen Vorschriften beachtet werden Am Einschraub Thermometer k nnen im Fehlerfall aggres sive Medien mit extremer Temperatur und unter hohem Druck oder Vakuum anliegen...

Page 5: ...ren Die Installation des Einschraub Thermometers so ausf h ren dass die zul ssige Betriebstemperatur Umgebung Messstoff auch unter Ber cksichtigung von Konvektion und W rmestrahlung weder unter noch b...

Page 6: ...60751 T05 2 5 s T09 6 5 s Messbereich 50 150 C 58 302 F Elektrische Daten Anschluss Steckverbinder M12 4 polig Mechanische Daten F hlerdurchmesser 6 mm Geh usematerial Edelstahl Umgebungsbedingungen...

Page 7: ...tes to the user The screw in thermometer described in the guide has been designed and manufactured according to the state of the art All the components were subjected to strict quality and environment...

Page 8: ...sors etc are present the relevant regulations must be observed above and beyond all general rules When faults occur aggressive media having high temperature and under high pressure may be present Meas...

Page 9: ...when not under pressure Install the screw in thermometer such that the permissible operating temperature ambient measuring material is neither too hot nor too cold taking into account convection and...

Page 10: ...T05 2 5 s T09 6 5 s Measuring range 50 150 C 58 302 F Electric data Connector M12 4 pole Mechanical data Probe diameter 6 mm Housing material Stainless steel Ambient conditions Ambient temperature 40...

Page 11: ...on enfichable La pr sente notice Guide d utilisation Le thermom tre visser d crit dans la pr sente notice d utilisation est construit et fabriqu d apr s les connaissances les plus r centes Tous les co...

Page 12: ...ifiques de compresseurs etc il convient de respecter outre l ensemble des r glementations g n rales galement les prescriptions en vigueur En cas de d faut des produits agressifs avec une temp rature e...

Page 13: ...ure de service admissible environnement produit mesur y compris en tenant compte de la convection et du rayonnement thermique ne soit pas d pass e par le haut ou par le bas Exemple de montage Fig 4 b...

Page 14: ...2 5 s T09 6 5 s Plage de mesure 50 150 C 58 302 F Caract ristiques lectriques Connecteur de raccordement M12 4 p les Caract ristiques m caniques Diam tre de sonde 6 mm Mat riau du bo tier Acier inoxy...

Page 15: ...ttore Il presente manuale Avvertenze per l utente Il termometro a vite descritto nel manuale d uso viene costruito e realizzato con le conoscenze pi recenti Durante la produzione tutti i componenti so...

Page 16: ...orme generali si devono rispettare le disposizioni vigenti In caso di difettosit al termometro a vite possono aderire fluidi aggressivi con temperature estreme e ad alta pressione o sotto vuoto spinto...

Page 17: ...etro a vite in modo che la temperatura di funzionamento ammessa ambiente sostanza di misura non venga oltrepassata n verso il basso n verso l alto anche considerando convezione e radiazione termica Es...

Page 18: ...s T09 6 5 s Campo di misura 50 150 C 58 302 F Dati elettrici Collegamento connettore M12 a 4 poli Dati meccanici Diametro sensore 6 mm Materiale corpo Acciaio inox Condizioni ambientali Temperatura am...

Page 19: ...ones para el usuario El term metro enroscable descrito en este manual de instrucciones ha sido dise ado y fabricado seg n los conocimientos m s recientes Todos los componentes est n sujetos a estricto...

Page 20: ...deben tener en cuenta las reglas generales sino tambi n las normas aplicables En caso de fallo con medios agresivos a temperatura extrema puede que sobre el term metro enroscable se apliquen alta pres...

Page 21: ...xceda ni se quede por debajo de la temperatura de servicio admisible entorno sustancia de medici n teniendo en cuenta la convecci n y la radiaci n t rmica Ejemplo de montaje Fig 4 b a c Longitud de mo...

Page 22: ...na medible 50 150 C 58 302 F Datos el ctricos Conexi n del conector M12 4 polos Datos mec nicos Di metro de sensor 6 mm Material de la carcasa Acero inoxidable Condiciones ambientales Temperatura ambi...

Page 23: ......

Page 24: ...e KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390 Fax 859 727 4823 technicalsupport balluff com CN Service Center China Balluff Shanghai trading Co ltd Room 1006 Pujian Rd 145 Shanghai 200127 P R...

Reviews: