7.7.3 Events
PD Update Timeout
With special process data values, the device automatically
checks whether the values are updated in the time period
specified by the device. If an update timeout is triggered as
a result, this is output via the following diagnosis
messages:
Event
Code
Event
Type
Event –
Description
– Remedy
Device
Status
0x1851
(6225)
Notification
Process Data
Update Timeout
– for information
purposes only
0 – Device is
operating
properly.
0x1852
(6226)
Warning
Multiple
Process Data
Update Timeout
– for information
purposes only
0 – Device is
operating
properly.
Tab. 7-23: Process data information and configuration – Events
PD Profile Selection after Change of Variant
If the variant of the device is changed, the currently set
profile is retained.
In the case that the corresponding PD profile is not valid
for this variant, the default profile for the corresponding
variant is selected.
Event
Code
Event
Type
Event –
Description
– Remedy
Device
Status
0x1850
(6224)
Notification
Process data
profile selection
cannot be
used – default
value is used.
0 – Device is
operating
properly.
Tab. 7-24: Process data information and configuration – Events
7
System Functions (continued)
7.7.4 Variant Dependence
The selection of the process data profile is dependent on
the variant – the PD-profile IDs are assigned to a device
variant.
Variant ID
PD Profile ID
2 (AdSS)
2 (AdSS)
3 (LSSC)
3 (LSSC)
4 (CM)
4 (CM)
Tab. 7-25: Process Data Information and Configuration – Variant
Dependency
PD Invalid
PD Inputs Invalid:
Input data (device-to-master) is marked as invalid if the
device status
(see section 7.1 on page 68) of the device
is
Failure
. In all other states, replacement values for the
data are output for which the content cannot be output
correctly.
BCS Q40BBAA-PIM20C-EP _ _ _ -GS04
Capacitive Proximity Switches
Summary of Contents for BCS Q40BBAA-PIM20C-EP-GS04 Series
Page 1: ...BCS Q40BBAA PIM20C EP___ GS04 deutsch Konfigurationsanleitung english Configuration Guide...
Page 2: ...www balluff com...
Page 3: ...BCS Q40BBAA PIM20C EP___ GS04 Konfigurationsanleitung deutsch...
Page 4: ...www balluff com...
Page 87: ...BCS Q40BBAA PIM20C EP___ GS04 Configuration Guide english...
Page 88: ...www balluff com...
Page 171: ......