![Balluff BAE SC-TL-F03 User Manual Download Page 74](http://html1.mh-extra.com/html/balluff/bae-sc-tl-f03/bae-sc-tl-f03_user-manual_3609618074.webp)
www.balluff.com
14
Control outputs (X6)
Six control outputs are available at terminal X6 pin 2, 3, 4, 5, 6 and 7.
Switching conditions can be set in the PRESELECTION MENU. The output Ctrl. Out1
–
6
are fast PNP outputs with a switching capability of 5
–
30 Volt / 200 mA per channel.
The switching voltage of the outputs must be applied to input terminal X6 pin 1 (COM+).
In case of switching inductive loads it is advisable to use external filtering of the coils.
Wiring of the
control-outputs
:
USB interface (X7)
A serial USB interface (mini USB) is available at terminal X7.
The USB interface can be used as follows:
•
For parameterization of the device during commissioning
•
To change parameters during operation
•
For reading out actual values via PC
The serial USB communication is done with a baud rate of "
115200 Baud
" and a
serial data format of "
8none1
" and cannot be changed by the user!