![Balluff BAE SC-TL-F03 User Manual Download Page 69](http://html1.mh-extra.com/html/balluff/bae-sc-tl-f03/bae-sc-tl-f03_user-manual_3609618069.webp)
www.balluff.com
9
Electrical Connections
The terminal screws should be tightened with a slotted screwdriver (blade width 2 mm).
DC Power Supply (X1)
The unit accepts DC supply from 18 to 30 V at the terminals X1 1 and 2. The power
consumption depends on the level of the supply voltage with aprox. 50 mA and the
additional current required at the Auxiliary Voltage Output.
All GND terminals are internally interconnected.
Hilfsspannungs-Ausgang (X2)
Two auxiliary voltages (24 VDC and 5 VDC) are available as encoder / sensor supply at
terminal X2 pins 7, 8 and 9. The 24 VDC output voltage depends on the device supply (see
technical data).