8-6 Customizing Your Application
MN762
Figure 8-3 PI Control Mode Example Wiring
1
2
3
4
5
6
7
+
-
1
2
3
4
5
6
7
+
-
1
2
3
4
5
6
7
+
-
Terminal mode P07 = 5, P08 = 0
Terminal mode P07 = 5, P08 = 1
Terminal mode P07 = 5, P08 = 3
+24V Output
+24V Output
+24V Output
O: Stop (disable)
C: Run (enable)
O: Stop (disable)
C: Run (enable)
O: PI Control
C: Preset Speed 1
O: PI Control
C: Local Speed Ref
PI Feedback Signal
(Analog Input 2)
PI Feedback Signal
+10V Output
+10V Output
Volts/
Current
(P44)
Volts/
Current
(P44)
Local Analog Ref
(Analog Input 1)
Local Analog Ref
0V
0V
O: Stop (disable)
C: Run (enable)
O: PI Control
C: Preset Speed 1
O: External Trip
C: Run Permit
PI Feedback Signal
0V
+10V Output
Volts/
Current
(P17)
1
2
3
4
5
6
7
+
-
+
-
+24V Output
Terminal mode P07 = 5, P08 = 9
O: Stop (disable)
C: Run (enable)
O: PI Reference
C: Preset Speed 1
(Analog Input 2)
PI Feedback 2
PI Feedback Signal
0V
+10V Output
(Analog Input 1)
Note: 2 Analog Feedback signals are provided to
Analog ln1 and Analog ln2. Feedback loop is
prioritized based on highest value of Analog ln1
and Analog ln2.