Installation 2-15
2 Wire Run/Stop Connections
Parameter 21 - Operating Mode = 2 or 3
Parameter 41 - Accel/Decel/Coast select = 3 or 7
CM
FWD
REV
PS3
PS2
PS1
V+
MOL
Shield
Forward
Reverse
Ramp Select
Speed Select
Speed Select
J19
Pull–Up Logic
CM
FWD
REV
PS3
PS2
PS1
V+
MOL
Shield
Forward
Reverse
Ramp Select
Speed Select
Speed Select
J19
Pull–Down Logic
See recommended tightening torques for terminal connectors.
Speed Select
PS2
PS1
Function
Open
Open
Keypad or
Analog Command Input
Open
Closed
33 - Preset Speed #1
Closed
Open
34 - Preset Speed #2
Closed
Closed
35 - Preset Speed #3
Ramp Select
PS3
Function
Open
42 - Accel Time #1 Active
Closed
43 - Decel Time #1 Active
Open
44 - Accel Time #2 Active
Closed
45 - Decel Time #2 Active