Installation 2-3
Terminal and Jumper Locations
Figure 2-2 shows the location of the power terminal strip , control
terminal strip , ground lug, and user adjustable jumper locations.
Only motor and input power should be connected to the power
terminal strip. Motor ground and input power earth ground
should be connected to the ground lug. Only external control
wiring should be connected to control terminal strip.
Figure 2-2 Terminal and Jumper Locations
J19
AC Line
L1, L2, L3
Motor
M1, M2, M3
Control
Terminals
Wiring Considerations
Interconnection wiring is required between the motor control, AC
power source, motor, host control and any operator interface
stations. Use listed closed loop connectors that are of
appropriate size for wire gauge being used. Connectors are to
be installed using crimp tool specified by the manufacturer of the
connector. Only Class 1 wiring should be used.