www.baldormotion.com
8-8 Specifications
MN1902
8.1.9 Relay / general purpose output (X3)
All models
Unit
All models
Contacts
Normally closed
Contact rating (resistive)
1A @ 30VDC
or
0.5A @ 125VAC
Maximum carrying current
A
2
Maximum switching power
62.5AV, 30W
Maximum switching voltage
250VAC, 220VDC
Maximum switching current
A
2
Capacitance
(between open contacts, at 1kHz)
pF
0.5
Update interval
Software (Mint programs)
DRIVEOKOUTPUT
,
DRIVEENABLEOUTPUT
,
GLOBALERROROUTPUT
,
MOVEOUT
,
MOVEOUTX
,
MOVEPULSEOUTX
,
PULSEOUTX
functions
PLC Task functions
Immediate
Equivalent to
LOOPTIME
:
1ms (default) or 2ms
Programmable
8.1.10 Serial RS232 interface (X6)
All models
Unit
All models
Signal
RS232, non-isolated CTS/RTS
Bit rate
Baud
9600, 19200, 38400, 57600
8.1.11 Serial RS485 interface (X6)
All models
Unit
All models
Signal
4-wire RS485, non-isolated
Bit rate
Baud
9600, 19200