3-36 Basic Installation
MN1902
3.9.9 Preventing a program running at startup
Flex
+
Drive
II
only
:
If switches 5 and 9 are set to On and switch 8 is set to Off, any program already in the
Flex+Drive
II
that contains an Auto command will be prevented from running automatically at
startup.
It is possible for normal (Baldor Binary Protocol) serial communication to be lost if bit 5 of the
Mint keyword
COMMSMODE
has been set. This can occur when alternative communication
protocols have been used. This DIP switch procedure will clear bit 5, restoring normal serial
communication.
On
5
Reapply power. Mint program
with Auto command will not run.
1.
2.
On
9
3.
Off
8
Remove
power.
Figure 23 - Preventing the Auto command from running a stored Mint program, or restoring
normal serial communication