Section 3
Specifications and Product Data
Specifications and Product Data 3-1
MN1221
Identification
DBSC Series
Power Supply
BPS
XX
Input AC Power
(2=230VAC 60/50Hz)
(3=460VAC 60Hz/400VAC 50Hz)
Continuous DC Current Rating
Power Supply
X
X
0 = 230VAC Logic Power
1 = 115VAC Logic Power
03 3000
30
Amperes
05 3000
50
Amperes
06 2000
60
Amperes
10 2000
100
Amperes
Rating
DBSC
Continuous DC Current
Specifications
BPS20
BPS30
Description
Unit
060
100
030
050
Input Bus Voltage – Nominal (Range)
VAC
230 (3
f
)
(180-264; 60Hz
180-230; 50Hz)
460 (3
f
)
(400-528; 60Hz
340-457; 50Hz)
Input Frequency
Hz
50 / 60
±
5%
Nominal Output Bus Voltage
VDC
320
650
Nominal Output Bus Current
A
RMS
60
100
30
50
Peak Output Bus Current
A
RMS
120
200
60
100
Input Logic Voltage – Nominal (Range)
VAC
115 (+6% –10%; 60Hz only 1 phase)
230 (+6% –10%; 50/60Hz 1 phase)
Input Logic Current – Nominal (Range) *
AMP
2.4A (@115) or 1.2 (@230)
Output Logic
VDC
+24 (+20% – 15%)
Output Logic
ADC
6.9 (for 3 Controls) 8.0 (for 5 Controls)
Mounting
–
Panel or Thru Wall
Package Size
B
Weight
lb(kg)
33(15)
Dynamic Brake Switching Threshold
On
Off
VDC
388
375
776
750
Dynamic Brake Peak Power
kVa
22.8
38
22.8
38
Dynamic Brake Maximum Switching Current
A
peak
60
100
30
50
Dynamic Brake Maximum Duty Cycle
%
25
25
Dynamic Brake Maximum Inductive Load
µ
H
100
Operating Temperature Range
°
C
+0 to 40. Above 40
°
C, derate the continuous and peak
output current by 2.5% per
°
C above 40
°
C.
Maximum ambient is 50
°
C.
Storage Temperature Range
°
C
–25 to +70
Humidity
%
10% to 90% non-condensing (IEC68–2–38)
Class of Protection (Enclosure)
IP20
Operating Altitude
Feet
(Meters)
To 3300 feet (1000 meters). Derate the continuous and
peak output current by 1.1% for each 330 feet
(100 meters) above 3300 feet (1000 meters).
Shock
10G (DIN IEC 68–2–6/29)
Vibration
1G @ 10 – 150 Hz (according to DIN IEC 68–2–6/29)
All values at 25
°
C unless otherwise stated.
* Maximum surge current <150msec = 15A (BPS20); 30A (BPS30)