2-6 Installation
MN1221
VCC and X10 Connections DC power connections are shown in Figure 2-4. Copper bus bars connect VCC+, VCC–
and GND between each module from the BPS to the last control. X10 connections are
daisy chained from the BPS to each control as shown.
Figure 2-4 Copper Bus Bar Installation and X10 Connections
DBSC
Control
BPS
See Terminal Tightening Torques
in Section 3 of this manual.
VCC+
VCC–
VCC+
VCC–
DBSC
Control
X10
1
2
3
4
X10
1
2
3
4
X10
1
2
3
4
See Section 3 for correct bus bar
length information.
If an optional 24VDC power supply or battery backup is used instead of the BPS, the
connections to X10 must be made as shown in Figure 2-5. This allows position
information and other memory related information to be stored when AC power is
removed from the BPS.
Figure 2-5 External 24VDC connections (not BPS)
X10
1
2
3
4
External 24VDC
Supply
Jumpers must be installed to prevent a fault condition.
(+)
(–)
Dynamic Brake Resistor
An external DB (Dynamic Brake) resistor must be installed to dissipate excess power
from the DC bus during motor deceleration operations. For selection of the DB resistor,
refer to the specifications located in Section 3 of this manual. DB hardware is connected
at the R1 and R2 terminals.