background image

Page 5

56016-01_97_A

G

C

G

C

G

C

G

C

RED AC

WHT AC

T

BLK AC

J32

J61

J62

T1

SWITCHBANK A

J11

J66 J65

J15

J16

J25

J63 J64

J33 J34

J36

J37

J35

BALBOA INSTRUMENTS, INC.

VS500Z
P/N  22972 REV D

MADE IN U.S.A

COPYRIGHT 2005

S1

J6

J7

J8

J44

J60

J22

U4

HTR2

HTR1

J101

J100

TB1

FUSE .3A 250V

FUSE 20A 250V

F

US

E 3A 250V

E.GN

D

CLASS G   FUSE 30A

F5

F4

K6

K1

K8

K9

K5

J23

J74

J73

J46J46

F1

J29

J47

J50

F7

J17/2

6

J20

J1A

J10

J13

J2A

EXT.

RLY

TST

AUX. F

SEN. A

SEN. B

VAC

W1

W7

W10

J1

J2

W2

W3

G

C

W4

K4

K2

K3

Balboa

F2

J12

1

2 3

J43

2-SPD

EXT RLY

J1

8

TORQUE
RANGE
FOR TB1:
27-30 IN. LBS.

HO
T

B

LAC

K

N

EUTRAL

WHITE

HO
T

RED

G

C

VS5xxD mode

Blower

G

R

B

W

J1

W1

J7

J6

F30A 480V

X-P332
PN 55137

P/N 22909 REV B

2-Spd P2

5.5 kW

Heater rated @ 240V
(Approx. 1.4kW @ 120V)

Audio VisualAudio Visual

Circ.Pump

Ozone

Ozone and Circ Pump must be same voltage.
Do not remove Fuse F7 (20A)

12V 

Light

2-Spd P1

PCBA Rev D & E only.
Black jumper required.
Do not remove.

Wiring Configuration and DIP Settings

Setup 1 (As Manufactured)

s 60UMP3PEED
s 60UMP3PEED
s 6"LOWER

s 6/ZONE
s 63PA,IGHT
s 6!<6

(Stereo)

s 6K7(EATER
s 6,$6,$-AIN0ANEL
s 6#IRC0UMPOPTIONAL 

A1, Test Mode OFF
A2, See Table 1
A3, N/A

A7, J17/26 Disabled

A10, See Table 1

A9, Non-Circ Mode

A5, 2-speed P1

Panel Button Assignments

1=Time
2=Mode/Prog
3=Temp Up
4=Temp Down

5=Light
6=Pump 1
7=Pump 2
8=Unused

Panel Button Positions

1

2

3

4

8

6

5

7

100

94
43

SSID #

VS51x/VS5xxS/VS5xxD

Compatible

J12

1

2

3

Memory
Reset

J43

A7, J17/26 Enabled

8=J17/26

120 Volt Connections

240 Volt Connections

Black AC Jumpers 

12 Volt Connections

Relay Control Wires

Wiring Color Key

Typically Line voltage

Typically Line voltage for 2-speed pumps

Neutral (Common)

Ground

Note flat sides in connector

Board Connector Key

1

2

3

4

WARNING: 

Main Power to system should be turned OFF BEFORE adjusting DIP switches.

WARNING: 

Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

Summary of Contents for VS520DZ

Page 1: ...f 04 08 2008 Template used 40600_P pdf 01 07 2008 Balboa Instruments System PN 56016 01 System Model VSP VS520DZ YCAH Software Version 43 EPN 2765 Base PCBA PN 55152 01 PCB VS500Z PN 22972 Rev D or E Base Panels VL801D Serial Deluxe PN 54108 VL802D PN 54528 ...

Page 2: ...By Changes Made 56016 1954 09 20 2006 Balboa New system 56016 2528 09 25 2007 Balboa Update to 48A serviceYCAH 56016 2528 10 05 2007 Balboa Software update to v41 A5 ON 56016 2528 10 18 2007 Balboa Software revert to v39 56016 01 2765 04 08 2008 Balboa Software update to v43 ...

Page 3: ... NEUTRAL GROUND System Outputs BALBOA INSTRUMENTS INC VS500Z P N 22972 REV D MADE IN U S A COPYRIGHT 2005 J7 J8 J44 J60 J22 U4 FUSE K8 K5 J1A J10 J13 J2A EXT RLY AUX F SEN A SEN B VAC J1 J2 W2 W3 J12 1 2 3 2 SPD EXT RLY J18 Basic System Features and Functions Setup 1 As Manufactured s 6 0UMP 3PEED s 6 0UMP 3PEED s 6 LOWER s 6 ZONE s 6 3PA IGHT s 6 6 Stereo s 6 K7 EATER Optional Devices s 6 IRC 0UM...

Page 4: ... that is a VS511SZ at version 38 s Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is configured for a heater effectively between 1 and 3 kW should appear for all VS models running at 240VAC should appear for all VS models running at 120VAC as well as all GS models A heater which is rated at 4 kW at 240VAC will function as a 1 kW heate...

Page 5: ...2 Spd P1 PCBA Rev D E only Black jumper required Do not remove Wiring Configuration and DIP Settings Setup 1 As Manufactured s 6 0UMP 3PEED s 6 0UMP 3PEED s 6 LOWER s 6 ZONE s 6 3PA IGHT s 6 6 Stereo s 6 K7 EATER s 6 6 AIN 0ANEL s 6 IRC 0UMP OPTIONAL A1 Test Mode OFF A2 See Table 1 A3 N A A7 J17 26 Disabled A10 See Table 1 A9 Non Circ Mode A5 2 speed P1 Panel Button Assignments 1 Time 2 Mode Prog ...

Page 6: ...g DIP switches incorrectly may cause abnormal system behavior and or damage to system components sRefer to Switchbank illustration on Wiring Configuration page for correct settings for this system sContact Balboa if you require additional configuration pages added to this tech sheet Panel Button Positions Aux Panel Information Panel Button Assignments 1 Time 2 Mode Prog 3 Temp Up 4 Temp Down 5 Lig...

Page 7: ... J29 See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC The voltage to the ozone connector can be changed in the field if required W2 just needs to be set for the required voltage WARNING Changing the voltage of the ozone connector also effects the voltage su...

Page 8: ...N 54108 with Overlay PN 10763 s Connects to Main Board terminal J1 only S ETUP 1 Blower Time Warm Mode Prog Cool Jets 1 Light Jets 2 VL802D PN 54528 with Overlay PN 11789 s Connects to Main Board terminal J1 only Panels with back lighting bulbs installed should never be plugged into J2 Use J1 only If the backlight bulbs are removed then both J1 and J2 may be used ...