Page 18
normally.
dr
dr
HEATER
MAY BE
DRY
WILL
RETEST
SHORTL
Y
Possible inadequate water,
poor flow, or air bubbles in
detected in the heater. Spa is
shut down for 15 minutes.
If water level is normal, make
sure all pumps have been
primed. Press any button to
reset. This message will reset
within 15 minutes. If problem
persists, contact your dealer
or service organization.
dy
dry
HEATER
DRY
SERVICE
RQD
Inadequate water detected in
heater. (Displays on third
occurrence of dr message.)
Spa is shut down.
Follow action required for dr
message.
Spa
will
not
automatically reset. Press any
button to reset manually.
IC
ICE
FREEZE
COND
"Ice"
-
Potential
freeze
condition detected.
No
action
required.
All
equipment will automatically
activate regardless of spa
status. The equipment stays
on 4 minutes after the sensors
detect
that
the
spa
temperature has risen to
45°F/7.2°C or higher. An
optional freeze sensor may be
added to protect against
extraordinary
freeze
conditions. Auxiliary freeze
sensor protection is advisable
is colder climates. See your
dealer for details.
PRIMING
MODE
TAKES 4
MIN
When your spa is first
actuated, it will go into priming
mode.
HEATER
DRY
SERVICE
RQD
Inadequate water detected in
heater. (Displays on third
occurrence of dr message.)
Spa is shut down.
Follow action required for dr
message.
Spa
will
not
automatically reset. Press any
button to reset manually.
DRAININ
G
The pump is on during
Standby Mode to assist in
draining the spa
Pres Jets 1 to turn of the
pump when water has drained
(or power of the spa)
CHKSUM
FAIL
Firmware install problem
Contact your dealer or service
organization.