background image

 

 

O

O

PERATION

PERATION

 

 

MANUAL

MANUAL

 

 

 

 

RLS201103    En.A 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Due to our continuous improvement programs, all models, operation, and/or specifications 

are subject to change without prior notice. 

Summary of Contents for VS501Z

Page 1: ...O OPERATION PERATION MANUAL MANUAL RLS201103 En A Due to our continuous improvement programs all models operation and or specifications are subject to change without prior notice...

Page 2: ...DZ Z GL8000 GL8000 Other _________________ Other _________________ T a b l e o f C o n t e n t s T a b l e o f C o n t e n t s Electrical Installation Electrical Installation Requirements Requirements...

Page 3: ...cal codes The following information is provided for hooking up the electrical power supply to your new spa WARNING Do not turn on the power to your spa until you are told to do so later in this Operat...

Page 4: ...0 mm2 380V 50 60Hz 16A 3 3x30A 5 x 6 0 mm2 380V 50 60Hz 32A 3 3x60A 5 x 10 0 mm2 REQUIREMENTS Caution Your spa must be wired by a qualified and licensed electrician and according to the instructions...

Page 5: ...ngs while installing power to your spa 5 After your spa has been positioned route lines through the knockout on the left or right front corner of your spa 6 Connect the electrical power to your spa EL...

Page 6: ...h the non metallic conduit strip 10mm of insulation off one end of each lead wires 5 Connect the lead wires to the proper terminals as indicated by the wiring diagram on the back of the control box co...

Page 7: ...Page 6 compliance with the National Electric Code NEC and all local codes 7 Close the control box cover and secure with screws 8 Electrical connection is now complete...

Page 8: ...S e r v i c e C o n f i g u r a t i o n o n f i g u r a t i o n O p t i o n s O p t i o n s Default Setting Single Service 1 x 16 Amp Single Service 1 x 32 Amp Dual Service 2 x 16 Amp 3 Phase Service...

Page 9: ...e 2 x 16 Amp 5 Wires 2 Lines 2 Neutrals 1 Protective Earth Protective Earth wire Green Yellow must be connected to system ground terminal as marked The heater runs on service line L1 while all other e...

Page 10: ...de a neutral wire with a line to neutral voltage of 230VAC The heater runs on service line L1 All main board equipments run on service line L3 Addtional equipment such as expansion boards run on servi...

Page 11: ...r VS GS5xxZ system VS GS5xxZ system DIP Switch A10 must be OFF GL8000 system DIP Switch A2 A3 and A4 can be ON DIP Switch A11 must be OFF O p e r a t i n g I n s t r u c t i o n s O p e r a t i n g I...

Page 12: ...button Temp Set 80 F 104 F 26 C 40 C The start up temperature is set at 100 4 F 38 C The last measured water temperature is constantly displayed on the LCD NOTE The water temperature displayed is curr...

Page 13: ...ts the spa Or system will revert to previous mode after 1 hour Preset Filter Cycles For VS GS5xxZ and VS GS5xxSZ series only The first preset filter cycle begins 6 minutes after the spa is powered up...

Page 14: ...e the display stops flashing Each press of the button will continue to either raise or lower the set temperature If the opposite direction is desired allow the display to revert to the current water t...

Page 15: ...the button once to turn the blower on Press the button a second time to turn the blower off NOTE If left running the blower will automatically turn off after 15 minutes Aux If equipped Press the butto...

Page 16: ...right side up display Freeze Protection GL8000 system only If the temperature sensors within the heater detect a low enough temperature then the pump s and the blower automatically activate to provid...

Page 17: ...ify more common sources of trouble yourself if you choose to do so Message Meaning Action Required VS GS5 xxZ VS GS5x xSZ DZ GL8000 No message on display Power has been cut off to the spa The control...

Page 18: ...into the Sensor B jack is not working If the problem persists contact your dealer or service organization May appear temporarily in an overheat condition Sn SnS SENSOR SYNC Sensors are out of balance...

Page 19: ...automatically activate regardless of spa status The equipment stays on 4 minutes after the sensors detect that the spa temperature has risen to 45 F 7 2 C or higher An optional freeze sensor may be a...

Page 20: ...NFIG ERROR Configuration error Spa cannot start up Contact your dealer or service organization GFCI FAILURE Spa could not trip GFCI Contact your dealer or service organization Continued operation may...

Reviews: