24
03.17
The water flow is low – M016**
There may not be enough water flow through the heater
to carry the heat away from the heating element. Heater
start up will begin again after about 1 min. See “Flow Re-
lated Checks” below.
The water flow has failed* –
M017**
There is not enough water flow through the heater to car-
ry the heat away from the heating element and the heater
has been disabled. See “Flow Related Checks” below. After
the problem has been resolved, reset the message*.
The heater may be dry* –
M028**
Possible dry heater, or not enough water in the heater
to start it. The spa is shut down for 15 min. Reset this
message* to reset the heater start-up. See “Flow Related
Checks” below.
The heater is dry* – M027**
There is not enough water in the heater to start it. The spa
is shut down. After the problem has been resolved, you
must reset the message* to restart heater start up. See
“Flow Related Checks” below.
The heater is too hot* –
M030**
One of the water temp sensors has detected 118°f (47.8°C)
in the heater and the spa is shut down. You must reset the
message* when water is below 108°f (42.2°C). See “Flow
Related Checks” below.
Flow-related checks
Check for low water level, suction flow restrictions, closed
valves, trapped air, too many closed jets and pump prime.
On some systems, even when spa is shut down by an error
condition, some equipment may occasionally turn on to
continue monitoring temperature or if freeze protection
is needed.
* Some messages can be reset from the panel. Messages
that can be reset will appear with a Clear Icon at the bot-
tom of the Message Screen. Press the Clear Icon text to
reset the message.
**M0XX is a Message Code.
Codes like this will be seen in the Fault Log
Error
Message Code: 30
The heater is too hot