![Balboa Water Group SpaTouch2 User Manual Download Page 28](http://html1.mh-extra.com/html/balboa-water-group/spatouch2/spatouch2_user-manual_3540143028.webp)
Manufactured under one or more of these patents.
U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614,
Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
42281_A | Compatible with SpaTouch 1 & 2
28
03.17
Qualified Technician Required for Service and Installation
Basic Installation & Configuration
Guidelines
Use minimum 6AWG copper conductors only.
Torque field connections between 21 and 23 in lbs.
Readily accessible disconnecting means to be provided at time
of installation.
Permanently connected power supply.
Connect only to a circuit protected by a Class A Ground Fault
Circuit Interrupter (GFCI) or Residual Current Device (RCD)
mounted at least 5’ (1.52M) from the inside walls of the spa/hot
tub and in line of sight from the equipment compartment.
CSA enclosure: Type 2
Refer to Wiring Diagram inside the cover of the control enclosure.
Refer to Installation and Safety Instructions provided by the spa
manufacturer.
Warning:
People with infectious diseases should not use a spa or hot tub.
Warning:
To avoid injury, exercise care when entering or exiting the spa or
hot tub.
Warning:
Do not use a spa or hot tub immediately following strenuous
exercise.
Warning:
Prolonged immersion in a spa or hot tub may be injurious to
your health.
Warning:
Maintain water chemistry in accordance with the Manufacturers
instructions.
Warning:
The equipment and controls shall be located not less than 1.5
meters horizontally from the spa or hot tub.
Warning! GFCI or RCD Protection.
The Owner should test and reset the GFCI or RCD
Warning! Shock Hazard!
No User Serviceable Parts.
Do not attempt service of this control system. Contact your
dealer or service organization for assistance. Follow all
owner’s manual power connection instructions. Installation
must be performed by a licensed electrician and all grounding
connections must be properly installed.
CSA Compliance/Conformité
Caution:
• Test the ground fault circuit interrupter before each use of
the spa.
• Read the instruction manual.
• Adequate drainage must be provided if the equipment is to
be installed in a pit.
• For use only within an enclosure rated CSA Enclosure 3.
• Connect only to a circuit protected by a Class A ground
fault circuit interrupter or residual current device.
• To ensure continued protection against shock hazard, use
only identical replacement parts when servicing.
• Install a suitably rated suction guard to match the
maximum flow rate marked
Warning:
• Water temperature in excess of 38°C may be injurious to
your health.
• Disconnect the electrical power before servicing.
Attention:
• Toujours verifier l’efficacite du disjoncteur differentiel avant
d’utiliser differentiel avant d’utiliser le bain.
• Lire la notice technique.
• Lorsque l’appareillage est installe dans une fosse, on doit
assurer un drainage adequat.
• Employer uniquement a l’interieur d’une cloture CSA Enclo
sure 3.
• Connecter uniquement a un circuit protege par un disjoncteur
differentiel de Class A.
• Afin d’assurer une protection permanente contre le danger
de shock electrique, lors de l’entretien employer seulement
des pieces de rechange identiques.
• Les prises d’aspiration doivent etre equipees de grilles
convenant au debit maximal indique.
Avertissement:
• Des temperatures de l’eau superieures a 38°C peuvent pre
senter un danger pour la sante.
• Deconnecter du circuit d’alimentation electrique avante
l’entretien.
Warning/Advertissement:
• Disconnect the electric power before servicing. Keep access
door closed.
• Deconnecter du circuit d’alimentation electrique avant
l’entretien. Garder la porte fermer.