44
Enter the Parameter Setting Interface
In the parameter setting state, when the parameter to be set begins to flash, press the "up" or "down"
key to adjust the parameter value. Press the "mode" key to switch among the to-be-set parameters. Press
the "mode" key two times (the interval between the two pressing actions should be shorter than 0.3
seconds) to exit the parameter setting state.
* In the parameter setting state, if no operation is performed to the display for 10 seconds, the display
will return to the normal riding state.
Data Reset:
After pressing the "mode" key 2 times (the interval between the two pressing actions should be
shorter than 0.3 seconds), the display enters the MENU state. In this state, the speed field displays tC
and then also displays y after pressing the "up" key. At this moment, the temporary data, including
maximum speed (MAXS), average speed (AVG) and single-trip distance (TRIP) can be cleared. After
this setting, press the "mode" key for shorter than 0.3 seconds to enter the km/mile setting interface.
If the user has never made any reset operation, the single trip distance and the accumulated riding time
will be automatically cleared when the accumulated riding time exceeds 99 hours and 59 minutes.
*When the display or the bicycle powers off, the above-mentioned data won't be cleared!
Km/ mile:
When the speed field displays S7, press the “up” or “down” key to switch between km/h and
mile/h or km and mile.
After this setting, press the "mode" key for shorter than 0.3 seconds to enter the setting interface
of light sensitivity.