background image

UniMod 01/I

 

 

 

 

 

COPYRIGHT 

 

Copyright © 2019 

 Baer Energie- & Messtechnik GmbH.  

All rights, including those originating from translation, (re)-printing and copying of this document or 
parts thereof are reserved. No part of this manual may be copied or distributed by electronic, me-

chanic, photographic or indeed any other means without prior written consent of 

 Baer 

Energie-  &  Messtechnik  GmbH.  All  names  of  products  or  companies  contained  in  this  document 
may be trademarks or trade names of their respective owners. 

 

 

Note  

Based  on  its  policies, 

  Baer  Energie-  &  Messtechnik  GmbH  develops  and  improves 

their  products  on  an  ongoing  basis.  In  consequence, 

  Baer  Energie-  &  Messtechnik 

GmbH preserve the right to modify and improve the software product described in this document. 
Specifications  and  other  information  contained  in  this  document  can  change  without  prior  notice. 
This document does not cover all functions in all possible detail or variations that may be encoun-
tered during installation, maintenance and usage of the software. 

Under no circumstances whatsoever will 

 Baer Energie- & Messtechnik GmbH accept 

any liability for mistakes in this document or for any sub sequential damage arising from installation 
or usage of the software.  

  Baer  Energie-  &  Messtechnik  GmbH  preserves  the  right  to  modify  or  withdraw  this 

document at any time without prior announcement. 

 Baer Energie- & Messtechnik GmbH does not accept any responsibility or liability for 

the installation, usage, maintenance or support of third party products. 

 

 

Printed in Germany 

Summary of Contents for UniMod 01/I

Page 1: ...UniMod 01 I Modem Operation Manual E121801419062 Baer Energie Messtechnik GmbH Siemensstr 3 D 90766 Fürth Germany Phone 49 0 911 970590 Fax 49 0 911 9705950 Internet www baer gmbh com ...

Page 2: ...GmbH preserve the right to modify and improve the software product described in this document Specifications and other information contained in this document can change without prior notice This document does not cover all functions in all possible detail or variations that may be encoun tered during installation maintenance and usage of the software Under no circumstances whatsoever will Baer Ene...

Page 3: ...Power Supply Unit 5 3 Interfaces 5 4 Display 5 5 Installation Hints 5 6 Programming the Modem 6 7 SMS 11 8 Reset Function 12 9 Inserting the Interface Modules 12 10 Technical Data 13 11 Terminal Block 14 12 Phone Line Interface 14 13 Dimensions 15 ...

Page 4: ...UniMod 01 I 4 ...

Page 5: ...le uses signals RxD TxD CTS RTS GND DTR DCD DSR RS485 interface module M Bus interface module active can supply 20 devices max 10 old version Communication is possible with many standard protocols like SCTM LSV1 DLMS IEC1107 IEC60870 transparent reading etc 4 Display The following LEDs display the current operating status of the modem and give information about the data transfer Operate LED signal...

Page 6: ...ppressed This configuration allows for reading meters of type VDEW IEC1107 IEC62056 21 If you want to change this parameters you need a PC with terminal software e g UniModSet Windows HyperTerminal etc Moreover experiences with the Hayes AT modem command set are very rec ommended To establish connection between PC and modem you have to use A the parametering adapter with USB port 12823 B the param...

Page 7: ...the switch to left position 01L as shown in the picture Position 01L 3 Insert the 7 pole plug of the parametering adapter instead of the interface module The notch must point upwards 4 Then connect the 25 pole plug RS232 to the PC port and switch on the voltage supply at the modem 5 The UniMod 01 I can now be programmed with the software UniModSet 6 After programming switch off the UniMod and inse...

Page 8: ...onses e g as text or numbers Automatic unhook Transmission mode e g secured Data transmit control Then select in the menu Settings Interface the serial port e g COM1 and send Write the chosen device configuration to the UniMod 01 I Additionally you can receive Read the configu ration from a connected UniMod 01 I In the menu File the current configuration can be saved File save as An existing confi...

Page 9: ...ables the call ing modem to determine the data rate which is used to read the target device The modem leaves in direct mode all transmission parameters unchanged Data compression and error correction are disabled But beware In case of bad connection or noisy line it may be possible that the UniMod doesn t hang up after the call has finished At the end of every programming the settings have to be s...

Page 10: ...e new password It s length must be 6 to 12 characters Finally the modem requests for confirma tion CONFIRM Example Changing the password from modem1 to 12345678 AT C OLD PASSWORD modem1 NEW PASSWORD 12345678 CONFIRM 12345678 OK the new password has been taken Data Transmit Control DTC Data Transmit Control is a firmware integrated feature for supervising the online data transfer The feature preven...

Page 11: ...on is possible only at Germany area Deutsche Telekom German Telecom Standard RS232 Function DTR DCD X15 Norm X10 X20 DTR X21 DCD DSR Hook SMS Function UE UA X20 UE X21 UA Example 20mA interface with two meters and SMS input contact XXXXXXX XXXXXXX 1 10 9 8 7 6 5 4 3 2 80 270 VAC 60 375 VDC SMS 20mA 11 12 13 14 UniMod 01 I Interface 20mA Baudrate 9600 7e1 80VAC 270VAC 50 60Hz 60VDC 375VDC 2007 ...

Page 12: ...re sets Without flashes 24h reset every 24 hours standard 12h reset every 12 hours 6h reset every 6 hours Without jumper reset every 3 hours 9 Inserting the Interface Modules When inserting the interface modules their component side must be at the left side and wired ac cording the picture In the following sketch the components are at the left side RS232 20mA active 20mA pas RS485 M Bus active M B...

Page 13: ...D and RxD Transmission rate remote modem to UniMod 300 33600 bit sec V 21 V 22 V 22bis V 32 V 32bis V 34 tone or pulse dialling Transmission rate UniMod to connected device 300 to 19200 115200 Baud automatic baud rate detection Data format 7E1 8N1 8E1 Data compression V 42bis MNP5 Error correction V 42 MNP4 Password Possible Remote access Possible with restriction Data Transmit Control Possible Re...

Page 14: ...Line Interface TAE plug used for Germany only Standard configuration 1 a La white 2 b Lb brown Note Cable colours may be different Alternative RJ12 plug used Standard configuration 3 a La green 4 b Lb yellow Note Cable colours may be different ...

Page 15: ...UniMod 01 I 15 13 Dimensions Wall mounted housing DIN 43861 2 ...

Page 16: ...UniMod 01 I 16 ...

Reviews: