Programming with the software UniModSet/MetcomTSet
After program start, select the register tab
“Analogue / PSTN”. Then choose one of the standard
configurations („
Assign“, for E-Meters, Metcom MWT32 or M-Bus-Systems) or assign the follow-
ing parameters manually:
Baud rate, e.g.: 9600 Baud
Data format, e.g.: 7E1
Control, e.g.: ignore DTR, no handshake
Responses, e.g.: as text or numbers
Automatic unhook
Transmission mode, e.g.: secured
Data transmit control
Then select in the
menu „Settings - Interface“ the serial port (e.g. COM1) and send („
Write“) the
chosen device configuration to the UniMod 01/I
. Additionally you can receive („Read“) the configu-
ration from a connected UniMod 01/I.
In the
menu „File“ the current configuration can be saved („File save as...“).
An existing configuration can be loaded by means of
„File load“.
Experienced users can alter the device configuration with the internal terminal program using AT
commands.