UniMod 01/I
12
8. Reset Function
Optional it is possible to activate the time-controlled modem-reset. The functionality is activated by
the jumper and displayed by the Rst-LED (Rst-LED flashes every 10 seconds).
Reset-Timer
Jumper
Function
Rst-LED
Disable: without re-
sets
Without flashes
24h: reset every 24
hours (standard)
12h: reset every 12
hours
6h: reset every 6
hours
Without jumper: reset
every 3 hours
9. Inserting the Interface Modules
When inserting the interface modules their component side must be at the
left
side and wired ac-
cording the picture. In the following sketch the components are at the left side.
RS232
20mA active 20mA pas.
RS485
M-Bus active
M-Bus pas.
Pin used, connected
Pin used, not connected
Pin not used