33
29.04.2013 TB-b bta_bj_vogue_wave_engl_29042013.indd
Final assembly of the BADU
®
Jet vogue
1) After installing the jet housing.
2) Glue in the cable protection hose and the air line hose. (Fig. 9)
3) Mount the suction housing (107) onto the clamping ring. Respect the installation position (Fig.10)
4) Place the nozzle housing (102.1) onto the jet housing (1).
5) Insert the pneumatic hoses and cables of the floodlight through the protective hose (14) and seal using
the screwed cable gland (20).
6) Use clamp (8) to fasten the air hose to the factory-mounted air regulator (21).
7) Fasten the nozzle housing (102.1) to the jet housing (1) using the 4 self-tapping screws (95).
Tighten the self-tapping screws to just hand tight. Do not use force!
8) Guide the pneumatic hoses through the openings in the stainless steel trim (93) (light ON-OFF left;
pump ON-OFF right) and fasten to the corresponding buttons using the hose clamps (46).
(Fig. 12)
9) Place the stainless steel trim (93) on the suction housing and fasten to the nozzle housing using
the two screws (49).
Tighten the self-tapping screws to just hand tight. Do not use force!
Insert the two pneumatic buttons through the trim in the nozzle housing and turn clockwise to lock.
(Fig. 13)
10) Attaching the light cover (110) also fastens the stainless steel trim (93).
To do this, place the light cover (110) over the bullet nozzle and into the nozzle housing and fasten
using the two screws (112).
Tighten the self-tapping screws to just hand tight. Do not use
force!
(Fig. 13)
11) Fasten the decorative caps (113) into the light cover (110) as shown in Fig. 14 A-C. Note that there
are decorative caps for left (L) and right (R).
12) Attach cap for air regulator (Fig. 15)
13) Connect the jet pump (92) with the half fitting (98, 99, 100), the rubber bracket (79) and the
corresponding clamps (75) on the suction and pressure side to the jet housing.
14) Connect the pump motor according to the wiring diagram.
Ensure the correct direction of rotation with the three-phase motor!
Perform the rotation check only when the pump is completely full of water.
15) Switching on and off from the pool using pneumatic buttons:
Pump ON-OFF (38/1) - right button
Light ON-OFF (38/2) - left button
16) The air regulator (21) can be used to admit air to the nozzle.
The use of a lubricant is
recommended to make
it easier to insert the
pneumatic hoses and the
floodlight cable through the
protective hose.