27
29.04.2013 TB-b bta_bj_vogue_wave_engl_29042013.indd
2.8 Unauthorised modes of operation
The reliability of the delivered machine is guaranteed only if it is used in the manner intended as
described in Section 1 “General” of the Operating Manual.
The limit values specified in the datasheet must never be exceeded under any circumstances.
Referenced standards and other documents
DIN 4844 Part 2 Safety descriptions
Supplement 13
3. Transport and intermediate storage
To prevent damage to and loss of individual components, the original packaging must not be
opened until just before installation.
4. Description
The BADU Jet vogue / wave is a countercurrent swim unit that can be integrated into any pool.
A powerful jet pump is connected via a suction and pressure pipe to the plastic jet housing, which is
inserted flush into the pool wall (no risk of injury as no parts protrude into the pool).
The pool water is drawn into the housing at low speed by the jet pump through the outer circumferential
channel and it is returned into the pool through the nozzle under high pressure.
The jet pump is switched on and off by the pneumatic button integrated into the nozzle housing.
The delivery rate and hence the effect of the countercurrent unit can be individually controlled by the
adjustable nozzle. The air regulator can be used to admit air to the nozzle current.
To create a lighting effect, the BADU Jet vogue / wave features integrated underwater illumination.
The illuminant is a 2.5 Watt long-life LED lamp. This illumination is not a substitute for the swimming pool
illumination. The illumination can be switched on and off using the left button inside the nozzle housing.
A remote control, a handle, a detachable massage nozzle, massage hose, pulsating massage hose and
a detachable pulsator can also be supplied as options.
5. Planning, setup, fitting, installation
Control boxes and pumps must be installed in a dry, well aerated and ventilated room.
Condensation must be prevented.
An adequately dimensioned floor drain must always be provided to prevent backup when drain
-
ing off any leakage, overflow or other water volumes accumulating in the event of a malfunc
-
tion!
To guarantee sound functioning of the pneumatic buttons, the clearance between pool and control box
must not exceed 10 m.
The pneumatic hoses must be laid in a protective hose so that they can be easily replaced at a later
time.
If the pump is installed further away, the pipeline must be dimensioned accordingly so as to guarantee
a practically loss-free current.
Use bends instead of angles where possible!
Otherwise the countercurrent swim unit has less effect.
Target flow rate approx. 58 m³/h