2.2.6. Installing an Optional Splitter Kit
Splitter kits are made available which allow the MZ unit to take gas sample readings from several sample
points while utilizing just a single zone. These kits are designed for use ONLY in confined/defined spaces
with high potential for leaks, such as food cases, cold rooms, refrigeration rack rooms, etc. Bacharach’s
2-way (P/N 3015-5404) and 3-way (P/N 3015-5405) splitter kits are available as optional accessories. Refer
to instruction 3015-5415 (supplied with the kit) for detailed installation instruction.
2.2.7. Connecting the Water Trap
The water trap is an optional accessory for applications that result in water or condensation frequently
entering the intake lines. This is available in a manual style trap (P/N 0007-1655) which is manually
emptied once it has become filled. Install the water trap close to the unit for the most effective results. The
intake line may be cut where the user finds appropriate (preferably close to monitor). Each side of the
intake line should be inserted into the receivers on either side of the water trap. Secure tightly. A
replacement filter (P/N 0007-1656) for the water trap is available and is replaced by unscrewing the clear
plastic cup of the water trap, pulling the filter directly out (do not unscrew), and inserting the new filter into
place. Replace the cup of the water trap. If desired, an optional mounting bracket (0007-1657) may be
used to secure the water trap in place.
NOTE:
The termination filter (P/N 3015-3420) or end-of-line water stop filter (P/ N 3015-
5512) should be used, regardless of the presence of a wat er trap.
IMPORTANT:
Extreme or humid temperatures may cause water to condense in the tubes.
A water trap is highly recommended for use in these scenarios.
Summary of Contents for MultiZone
Page 52: ...Multi Zone Gas Monitors 46 P N 3015 5074 Rev 11 ...
Page 58: ...Multi Zone Gas Monitors 52 P N 3015 5074 Rev 11 ...
Page 60: ...Multi Zone Gas Monitors 54 P N 3015 5074 Rev 11 ...
Page 71: ...Multi Zone Gas Monitors P N 3015 5074 Rev 11 65 APPENDIX C SYSTEM MENU MAP ...
Page 72: ...Multi Zone Gas Monitors 66 P N 3015 5074 Rev 11 ...
Page 73: ...Multi Zone Gas Monitors P N 3015 5074 Rev 11 67 APPENDIX D AGENCY APPROVALS ...
Page 74: ...Multi Zone Gas Monitors 68 P N 3015 5074 Rev 11 ...
Page 76: ...Multi Zone Gas Monitors 70 P N 3015 5074 Rev 11 ...
Page 78: ...Multi Zone Gas Monitors 72 P N 3015 5074 Rev 11 ...