Multi-Zone Gas Monitors
6
P/N: 3015-5074 Rev 11
NOTE:
The pickup points located on the floor in the above illustration are examples for
refrigerants which are heavier than air. Placement of pickup points should be determined
based on characteristics of the gas being monitored and ambient conditions of the sampling
area. (Air=28.9 g/mole, CO
2
=44.0 g/mole, NH
3
=17.0 g/mole, and halogens = 100+ g/mole.)
1.6. Specifications
HGM-MZ Specifications
Product Type
Multiple refrigerant gases and multiple area monitoring system for low level continuous
monitoring of CFC, HCFC and HFC refrigerant gases used in most commercial
refrigeration systems. System design supports compliance to the refrigerant monitoring
requirements of ANSI/BSR ASHRAE 15-2007 and ASHRAE Safety Code 34-2007.
Sensitivity
All gases 1 ppm
Measuring Range
All gases 0 to 10,000 ppm
Accuracy
1
±1 ppm ±10% of reading from 0-1000 ppm
(R11, R22, and R113 ±10 ppm ±15% of reading 0-1000 ppm)
Gas Library
CFC:
HFP, R-11, R-12, R-113, R-114, R-502
HFC:
R125, R-134a, R236FA, R245Fa, R32, R-404a (HP62), R-407a, R-407c
(AC9000), R-410a (AZ20), R422a, R422d, R427a, R-507 (AZ50), R-508b
(SUVA95)
HCFC:
R-123, R-124, R21, R-22, R227, R-23, R-401a (MP39), R-402a (HP80),
R-402b (HP81), R-408a, R-409a, R-500, R-503
Halon:
H1211, H1301, H2402
Other:
FA188, FC72, H1234YF, N1230, R424A, R426A, R438A, CUSTOM
AGM-MZ Specifications
Product Type
The AGM-MZ provides multiple area monitoring system for low level continuous
monitoring of Ammonia gases used in most commercial systems.
Sensitivity
20 ppm
Measuring Range
25 to 10,000 ppm
Accuracy
1
±10 ppm ±10% of reading from 0-10,000 ppm
Gas Library
Ammonia (NH
3
)/R-717
CO
2
-MZ Specifications
Product Type
The CO
2
-MZ pro vides multiple area monitoring for low level continuous monitoring of
carbon dioxide gases used in most commercial systems. System design supports
compliance to the gas monitoring requirements of ANS/BSR ASHRE 15-1994.
Sensitivity
10 ppm
Measuring Range
300-8,000 ppm
Accuracy
1
±5 PPM ±5% of reading from 300-1000 ppm, ±10% of reading from 1001-3000 ppm
Gas Library
Carbon Dioxide (CO
2
)/R-744
1
At reference environmental conditions (25°C, 45% RH non-condensing, 1 ATM)
Summary of Contents for MultiZone
Page 52: ...Multi Zone Gas Monitors 46 P N 3015 5074 Rev 11 ...
Page 58: ...Multi Zone Gas Monitors 52 P N 3015 5074 Rev 11 ...
Page 60: ...Multi Zone Gas Monitors 54 P N 3015 5074 Rev 11 ...
Page 71: ...Multi Zone Gas Monitors P N 3015 5074 Rev 11 65 APPENDIX C SYSTEM MENU MAP ...
Page 72: ...Multi Zone Gas Monitors 66 P N 3015 5074 Rev 11 ...
Page 73: ...Multi Zone Gas Monitors P N 3015 5074 Rev 11 67 APPENDIX D AGENCY APPROVALS ...
Page 74: ...Multi Zone Gas Monitors 68 P N 3015 5074 Rev 11 ...
Page 76: ...Multi Zone Gas Monitors 70 P N 3015 5074 Rev 11 ...
Page 78: ...Multi Zone Gas Monitors 72 P N 3015 5074 Rev 11 ...