7. RS-232 OUTPUT
The C100 Series of scales come standard with an RS-232 output.
Specifications:
RS-232 output of weighing data
ASCII code
9600 Baud
8 data bits
No Parity
Connector: 9 pin socket
From C100
Pin 2 Output
Pin 3 Input
Pin 5 Signal Ground
To LP50
Pin 2 Input
Pin 3 Output
Pin 5 Signal Ground
Connection to the LP 50 printer
Set Parameter F2 to 9600 8n1 LP50
Set LP50 Dip SW 1,2, and 4 ON
Sample Print
LOCAL SCALE
ID: 123ABC
NAME:Text
12.456 kg NET
1.1234 g U.W.
11 PCS
TOTAL
- - - - - - - - - - - -
49.824 kg TW
44 TPC
4 No.