7.3.5 MENU
OTHER
MENU
OTHER
• SYSTEM INFORMATION
Displays the information on the system. End user cannot change these values.
• TIME / DATE
Displays time, date, motherboard temperature, power supply voltage.
• RESERVED
Menu for the exclusive use of the manufacturer.
• DIAGRAM
Displays the diagram of the measured flow rate.
• SIMULATION
MAG
converter has an integrated flow simulator which checks and sets the
pulse output to any connected device system.
When the flow simulator is being used, the counter values are not
increased.
• COMMUNICATIONS
» Baud rate RS485
Allows for the adjustment of the RS485 baud rate in a range between 2400 and
115.700 bps.
» MODBUS address
Allows for the adjustment of the address of the MODBUS communication in a
range between 1 and 255.
» DATA CONNECTION
(RS485/IrCOM)
Allows for the selection of the RS485 port or infra-red port for connection to pc.
Before starting the infra-red communication, make sure that the function
IrCOM of the converter has been enabled:
Menu
Other
Communication
Data connection
IrCOM.