10.  Wipe O-ring clean of debris before re-inserting 

patented HydroLock® plate on to junction box. 

Turn HydroLock® plate clockwise to lock in place 

under pins.

B.  For a drive-over installation, fill the hole around 

the fixture housing to 12” below the finished 

grade with clean fill dirt and tamp carefully to 

prevent settling of fixture. Pour concrete and 

finish as required flush with the top surface of 

the Yellow Installation Cover. 

 Note: Drive-over rated for 55,000 lbs. GVW 

(Standard flat lens rated for 35,000 lbs. 

GVW)

A.  For soil installation, fill and tamp soil to the 

appropriate height leaving room for sod, 

pavers, etc. to be level with the top of the 

Yellow Installation Cover.

 

Soil installation is NOT Drive-over rated!

Concrete/Drive-over

Soil

7.  Per DIG-IT Guide, backfill the gap between the 

bottom of housing and bottom of hole with 

sand for drainage.

8.  Rotate patented HydroLock® plate counter 

clockwise to allow notch in HydroLock® plate to 

clear pins on junction box. Pull to remove.

9.  Pull branch circuit wiring and external dimming 

controls into junction box.  Make watertight 

connections using waterproof wire connectors 

(provided) to leads on the interior patented 

HydroLock® plate. 

See wiring diagram.

TENAYA2® SERIES 

Housing Installation

Housing Rough-In (Continued)

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

LINE (BLACK)
COM (WHITE)

Hydrolock

Plate

GROUND (GREEN)

Black
White

Hydrolock

Plate

Green

Driver

White
Black
White
Blue
Green

LINE

COM

GROUND

Orange
Orange
Brown
Blue

Black
Gray

FIXTURE

FIXTURE

Green

Green

DIM + (RED)
DIM - (ORANGE)

DIM +

DIM -

WIRING DIAGRAM

Summary of Contents for Tenaya 2 Series

Page 1: ...rn off power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition The use of damaged components may cause an unsafe condition and void product warranty IMPORTANT SAFETY INFORMATION READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Do not block light emanating from...

Page 2: ...ve sufficient clearance to elevate housing to finished grade Top of yellow temporary cover level to finished grade 4 Raise housing on EMT to finished grade top of yellow temp cover Use bubble level on yellow temporary cover to aid in leveling housing 5 When top of yellow temporary cover is level with finished grade tighten screws on Stability Flange to secure housing to EMT Remove excess EMT as ne...

Page 3: ...be level with the top of the Yellow Installation Cover Soil installation is NOT Drive over rated Concrete Drive over Soil 7 Per DIG IT Guide backfill the gap between the bottom of housing and bottom of hole with sand for drainage 8 Rotate patented HydroLock plate counter clockwise to allow notch in HydroLock plate to clear pins on junction box Pull to remove 9 Pull branch circuit wiring and extern...

Page 4: ...Concrete Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power sup...

Page 5: ...he optical chamber horizontally 360 rotate the optical chamber to desired direction 8 For Optional Internal Cutoff Place internal cutoff louver in the top of the optical chamber in the desired direction of cutoff and install faceplate as normal Optional Internal Cutoff 7 Before Installation of faceplate clean solid silicone faceplate gasket see arrows and collar of debris for a proper seal FAILURE...

Page 6: ...n to 25 in lbs 5 Remove optic holder by loosening two 2 4 40 screws using a 0 05 Allen wrench 6 Carefully remove LED module from heatsink Do not pull on connector or wiring Handle with care Fragile Do not pull on connector or wiring Handle with care 7 Use small pick tool to push connector off LED board through two small slots behind connector Once loose lift connector upwards and off board 8 Place...

Page 7: ...Tighten 2 6 32 set screws to secure accessory bracket to OptiLock as shown 15 Before Installation of faceplate clean solid silicone faceplate gasket see arrows and collar of debris for a proper seal FAILURE TO DO THIS STEP WILL CAUSE FIXTURE TO FAIL AND VOID PRODUCT WARRANTY 13 If your Tenaya2 comes with optional accessory holder see Relamping with Accessory Holder to remove and install source To ...

Page 8: ...RUCTIONS 3 Insert up to 2 accessories into the accessory holder Accessories should rest on lip of accessory holder NOTE 1 Insert any accessory lens with the smooth side toward the LED 2 If using a honeycomb baffle position it farthest from the LED Accessory Replacement 4 Place accessory holder onto tabs on accessory bracket over optic 1 Pull accessory holder from accessory bracket 2 Optic should r...

Page 9: ...ighten two set screws 2 Install the faceplate using 3 16 Allen wrench and torque the faceplate screws in a cross pattern to 25 in lbs Rock Guard w Optical Opening Rock Guard Half Dome Glare Shield 1 Before installation of faceplate clean solid silicone faceplate gasket see arrows and collar of debris for a proper seal FAILURE TO DO THIS STEP WILL CAUSE FIXTURE TO FAIL AND VOID PRODUCT WARRANTY Fac...

Reviews: